Overview; Precautions; Components - Madrigal Imaging MP8 Instruction Manual

Crt installation
Hide thumbs Also See for MP8:
Table of Contents

Advertisement

Overview

This procedure will allow a qualified Madrigal Imaging dealer to install a CRT into a
MP8. Please read and understand all instructions outlined in this procedure before
attempting the installation.
Should you have questions about this procedure please contact the Madrigal Technical
Services Department.

Precautions

This CRT assembly replaces similar Panasonic 8" CRTs.
Check that the projector is TURNED OFF AND UNPLUGGED before performing this
procedure.
Projection CRTs contain a vacuum and pose a threat of flying glass if dropped. The use
of PROTECTIVE EYEWEAR is highly recommended when handling a CRT.
During the removal and installation of the CRT, it is important to insure that NO
MAGNETIC MATERIALS are brought close to the focus coil or permanent field
distortion will occur.
To reduce the chance of a HIGH VOLTAGE DISCHARGE, discharge the anode lead
(red high voltage lead) of the CRT to Chassis ground upon removal.

Components

The service CRT provided comes complete with factory-aligned components.
All components are clamped to the CRT and glued into place except for the deflection
yoke. The deflection yoke is left free for tilt adjustment.
Install the service CRT with the above components; do not attempt to remove or re-use
these components, as the physical alignment is critical to the performance of the
projector.
MP8 CRT Installation
Phone
Fax
Email
Check the original CRTs are 8" Panasonic.
Do not use to replace 9" CRTs (MP-9).
Deflection Yoke
Convergence Yoke
Electromagnetic Focus Coil
Stigmator / Flair Rings
860-346-0896
860-347-6251
madts@harman.com