Application Range - Kohler PRO 2.8 i Owner's Manual

Table of Contents

Advertisement

AE00812

Application range

When using the generator, make sure the total load is within rated output of a genera-
tor. Otherwise, generator damage may occur.
AC
Power factor
PRO 2.8 i
1
33 590 04
1
0.8–0.95
–2,500 W
–2,000 W
TIP
9 "–" means below.
9 Application wattage indicates when each device is
used by itself.
9 The simultaneous usage of AC and DC power is
possible but total wattage should not exceed the
rated output.
EX:
Frequency
9 The overload indicator light comes on when total
wattage exceeds the application range. (See page
19 for more details.)
760-021a
1 Overload indicator light
KohlerPower.com
0.4–0.75
(Efficiency 0.85)
–850 W
Generator rated output
Power factor
1.0
AC
0.8
DC
DC
Rated voltage
12 V
Rated current
10 A
2,500 VA
–2,380 W
–1,880 W
120 W
(12 V/10 A)
16

Hide quick links:

Advertisement

Table of Contents
loading