G.f.c.i. Receptacle Test - Kohler PRO 2.8 i Owner's Manual

Table of Contents

Advertisement

3
4
33
AE01007

G.F.C.I. Receptacle test

1. Start the engine.
1
2. Press the test button, then check the position of
the reset button.
2
1 Test button
763-105
2 Reset button
763-059
3. If G.F.C.I. operation is correct, push in the reset
button.
If the G.F.C.I. operates incorrectly, consult a
Kohler portable dealer.
Do not operate the generator with a faulty G.F.C.I.
circuit. Electric shock could occur. Have the gen-
erator repaired by a qualified mechanic.
KohlerPower.com
G.F.C.I. Reset
Button Position
after Test
3 Pop Out
4 Stay In
WARNING
G.F.C.I. Receptacle
Operation
Correct
Incorrect
33 590 04