Yamaha WaveRunner GP1300R Service Manual page 276

Hide thumbs Also See for WaveRunner GP1300R:
Table of Contents

Advertisement

TRBL
ANLS
TROUBLE ANALYSIS
SELF-DIAGNOSIS
With the engine running, press the select but-
ton 1 for 8 seconds and check if an error code
is indicated on the multifunction meter.
Code
01
Normal
13
Pickup coil malfunction
Engine temperature sensor
15
malfunction
Throttle position sensor (TPS)
18
malfunction
19
Incorrect battery voltage
Atmospheric pressure sensor
22
malfunction
Intake air temperature sensor
23
malfunction
47
Slant detection switch malfunction
48
Incorrect data transmission
Exhaust temperature sensor
53
malfunction
54
Stepping motor malfunction
55
Steering switch malfunction
59
Memory data malfunction
64
YPVS servomotor malfunction
Cooling water temperature sensor
65
malfunction
66
Stepping motor stuck closed
67
Stepping motor stuck open
If the Yamaha Diagnostic System is not used
to check the symptoms listed in the table, the
error codes can be checked easily with the
self-diagnosis in the multifunction meter. How-
ever, if there are numerous error codes dis-
played, be sure to check them with the
Yamaha Diagnostic System.
9-7