The second error (2ND) LED will come on if an over-torque condition occurs while the 60M LED is still lighted.
The 2ND LED will indicate to the technician that two consecutive over-torque situations have occurred. The
icemaker will be shut down at this time and will not restart unless the manual reset button is depressed.
W
COMPRESSOR
C
If the water level in the float reservoir drops to an unacceptable level, the WTR LED will go out, shutting the
icemaker off. Also, the BT LED will come on, preventing the icemaker from restarting for twenty minutes. If water
is restored, the WTR LED will come back on and flash to alert the technician that water to icemaker has been
lost. The icemaker will then restart at the end of the 20 minute time delay. The flashing WTR LED can be cleared
by pressing the reset button.
W
COMPRESSOR
C
Diagnostic sequence – Stage 9
INPUT
POWER
B
G
GRD
X
HI-TEMP SAFETY
T-STAT (W/C ONLY)
WHITE
FAN
BLACK
WHITE
M
BLACK
BLACK
1
R
M
ORANGE
L
S
S
BLACK
RED
BLACK
WHITE
Diagnostic sequence - Stage 10
INPUT
POWER
B
G
GRD
X
HI-TEMP SAFETY
T-STAT (W/C ONLY)
WHITE
FAN
BLACK
WHITE
M
BLACK
BLACK
1
R
M
ORANGE
S
L
S
BLACK
RED
BLACK
WHITE
WATER
SENSOR
CONTROL
RESET
GRD
BOARD
L1
L1
L2
L2
L2
L2
L2
COMPRESSOR
FAN
DRIVE
L2
L1
3
4
GEARMOTOR
WATER
SENSOR
PWR
RESET
GRD
DR
L1
L1
C
L2
CONTROL
20M
L2
BOARD
60M
L2
L2
2ND
L2
WTR
B-T
COMPRESSOR
B-E
FAN
DRIVE
L2
L1
3
WHITE
4
GEARMOTOR
BLACK
8
PWR
BIN T-STAT
DR
C
20M
60M
BIN SIGNAL
FROM DISPENSER
2ND
JUNCTION BOX
WTR
B-T
B-E
RED
RED
COMPRESSOR
SWITCH
WHITE
BLACK
BIN T-STAT
BIN SIGNAL
FROM DISPENSER
JUNCTION BOX
RED
RED
COMPRESSOR
SWITCH