16. Maintenance Monitor / Error History

This feature is available on appliances where a deluxe controller (MC70-2A or BC70-2A) is fitted,
enabling service personnel to locate the error history and fault find operational appliances.
NB. Use only one controller, when accessing the maintenance information /error history, as two or more remote controls may
cause incorrect operation.
To display Maintenance Information
1.
With the controller in the "OFF" position press the Water Temperature "DOWN"
(Cooler) button while holding the "ON/OFF" button to activate the maintenance
monitor. Press the "ON/OFF" button a second time to set the controller in the
"ON" mode. This feature can now be used with the appliance in operation.
2.
The maintenance number will be shown in the Water Temperature display.
3.
Data will be shown in the Clock display.
4.
To select the required maintenance number, press the Water Temperature "UP"
and "DOWN" buttons.
No.
Contents
01
Water flow sensor recognition flow
(Example 123 = 12.3L/min).
02
Hot water Outlet thermistor temperature
(Example 20 = 20°C)
03
Hot water combustion time
(Example 6 = 600 hours)
04
Hot water operation frequency
(Example 6 = 600 Operations)
05
Hot water fan frequency
*Note 1 Fan Frequency rpm Conversion
(rpm) = (Hz) x15
06
Remote control connection
*Note 2 Remote Control Connections
Additional remotes
" 0
Infinity REU-V2626W / HD200E REU-V2632WC
Display Monitor Contents
Bathroom Remote
1
Units
0.1L/min
°C
100 hours
100
Hz pulses/sec
none
Controls connected
Kitchen remote
No
1 "
Yes
- 34 -
Data Range
0~400
0~999
000~999
0~999
0~999 *Note 1
0 or 1 *Note 2
Display
"0"
"1"
Issue 1 - 10/10/03 ©Rinnai