Technical Data; Specifications - Profoto D4 1200 Air User Manual

Flash generator
Table of Contents

Advertisement

Technical data

All data is to be considered as nominal and Profoto reserves the right make changes
without further notice.

Specifications

Specifications
Energy
Energy Range
22
Energy Distribution
Asymmetry Range
Recycling time, 120V/60Hz
Recycling time, 230V/50Hz
Flash Duration t 0.5
Modeling Lamps Total W/Pack (max)
Modeling Lamps W/Head (max)
Modeling Light Modes
Energy Control Increments
Energy/Voltage stability
Guide number @ 2 meters/100
ISO with Magnum reflector
Specified data conditions
Input Power supply
www.profoto.com
D4 1200 Air
1200 Ws
8 f-stops
8 f-stops (18-
(9-1200Ws)
Socket A
9-1200Ws
Socket B
9-1200Ws
Socket C
9-600Ws
Socket D
9-300Ws
max 7.8 f-stops
0.07-1.2 s
0.07-1.2 s
1/7500-1/1000 s 1/4500-1/600 s 1/2700-1/350s
Max, Prop, ½ Prop, Max Prop, Off
1/10 and 1/1 f-stops
± 1/100 f-stop
90
Acute/D4 head, 120 or 230V AC
100-120V/200-240V, 50/60Hz (nominal)
D4 2400 Air
D4 4800 Air
2400 Ws
8 f-stops (36-
2400Ws)
4800Ws)
Socket A
18-2400Ws
36-4800Ws
Socket B
18-2400Ws
36-4800Ws
Socket C
18-1200Ws
36-2400Ws
Socket D
Socket D
18-600Ws
36-1200Ws
0.09-2.2s
0.12-4.4 s
0.09-2.2s
0.12-4.4 s
2000 W
500 W
128
4800 Ws
Socket A
Socket B
Socket C
180

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

D4 2400 airD4 4800 air