Service And Ventilation; Door And Seal; Testing The Tub - Ella's DELUXE SOAKING WALK IN TUB  Owner's Manual

Deluxe soaking walk in tub
Table of Contents

Advertisement

DRAIN ‐ SUBFLOOR ‐ DOOR – SEAL cont...
SERVICE ACCESS AND VENTILATION: 
It is the responsibility of the installer or owner to provide access for service required, per code.   Ella's 
Bubbles is not responsible for any costs related to obtaining access for repair.  The owner shall assume 
responsibility for such costs, and if appropriate, must seek recovery from the installer. 
DOOR AND SEAL:      
Please keep in mind that the door has been closed for an extended period of time throughout shipping 
and the tub has been stored in various temperatures.  When the tub is received, the door seal must be 
reformed and adjusted, as it may have possibly stuck to the frame throughout storage and shipping in 
various temperatures.  In cases such as these, the door seal must be released and rested with the door 
open.  It can be done by squeezing the seal with your finger tips and pulling it away from the door frame 
to regain its flexibility and original form.  It is highly suggested that the door be kept in the open position 
while the tub is not in use to increase the lifetime of the door seal and maintain its flexibility. 
 
TESTING YOUR WALK IN TUB 
 
 
All walk‐in bathtubs are factory tested for proper operation and watertight connections prior the 
packing and shipping. However, the unit must be retested by installer prior to installation.  Ella's Bubbles 
is not responsible for any defect that could have been discovered, repaired, or avoided by following this 
inspection and testing procedure. 
1. Place the walk‐in bathtub on a level surface near appropriate water and electrical supply and 
drainage.  It can be done in homeowner's driveway or in the bathroom, as well. 
2. If the tub comes with a flex drain, connect it to the existing home drain.  If not, run a temporary drain. 
Fill up the water 2 inches below to overflow hole. 
3. Do not install the bathtub if leaks are detected. 
Caution: If walk‐in bathtub is not resting on all six leveling feet, water will not drain properly and may 
cause the door to leak.  Never allow the weight of the tub to be supported by wood support stringers as 
this will result in product failure and void the warranty.  Verify the product is completely level by 
checking the tub deck surface and ensure all 7 leveling feet are touching the ground.  
Every tub is 100% water tested at the factory with all pumps in working condition.  However, 
transporting or carrying the tub may cause loose fittings, possible damages, or leaks.  It is the 
contractor's responsibility to water test the bathtub with all pumps running prior to finishing the tub 
and wall installation.  The contractor must make sure that all fittings by the pumps are retightened and 
the tub is leak proof.  Any water or air jets can be retightened to stop the leaks.   
 