OPERATION RANGES

The table below indicates the temperature and humidity ranges the air conditioner can be operated within.
Refer to the table for efficient use.
MODE
COOLING
HEATING
DEHUMIDIFYING
POWER SUPPLY
• Any damage occurs out of condition specified cannot be covered by product warranty. If the system
works continuously outside of conditions, its performance and reliability will be compromised.
• If the outdoor temperature is as low as 0°C, the heating capacity may drop depending on the
operating condition.
Effiel_IB_E_29147_10.08.08.indd 29
OPERATING CONDITIONS
Indoor temp: 18˚C~32˚C
Indoor humidity: below 80%
Outdoor temp: -15˚C~43˚C
Indoor temp: below 27˚C
Outdoor temp: -20˚C~24˚C
Indoor temp: 18˚C~32˚C
Indoor humidity: below 80%
Outdoor temp: -15˚C~43˚C
Single phase rated voltage
minimum and maximum limit
IF OUT OF CONDITIONS
- A safety device will stop continuously
the system functioning;
- Condensation may occur on the indoor
unit with risk to have either water blow
off or drops on the floor;
- A safety device will stop continuously
the system functioning;
- A safety device will stop continuously
the system functioning;
- Condensation may occur on the indoor
unit with risk to have either water blow
off or drops on the floor;
220-240V~, 50Hz
198V - 264V
appendix _29