Technical specifications

Radio transmission 915--928Mhz
Power output: 1000Mw
Type: Spread spectrum freq hopping
Security encryption: 56 bit DES
Handheld Battery: NI-MH
10 x AA 2300 Ma
Austel compliance N3884
Sed 900 fault Sequence
To be able to read the fault indication
You must wait for the ( chg led ) and ( Lbatt led )
to flash together 5 times
this will be followed by the Lbatt led
flashing a number of times ( 1-3 ) before the
process is repeated.
Please see Lbatt fault indication guide below
Chg led
flash together
flash together
flash together
flash together
flash together
Lbatt led
flash alone once = internal temp error
flash alone twice = Low Ppac mains
flash alone three times = Battery error
4