SERVICE MANUAL
.
Model: HC17SF10RB/HC27SF10RW/B
Chapter 6 Trouble shooting
6-1.Compressor parameter
Part Name
Check Method and Criterion (Ambient temperature : Room temperature 25°C)
Model
Compressor
L35C5L
Model
Starter
Current(max)
Voltage(max)
Model
Overload
Open
protector
temperature
Close
temperature
Main wiring
11±10%Ω
QP2-4.7
10 A
180 V
BT48-125A61D2
125±5℃
61±9℃
Issue
2014-3-10
Rev. Ref1403S005V0
Auxiliary wiring
7.75±10%Ω
11