2.4 ELECTRICAL & PHYSICAL DATA (SEE TABLE 1 & 2)
TABLE 1
(-)PNE ELECTRICAL AND PHYSICAL DATA
Model
Compressor
Phase
Number
Frequency
Rated Load
(-)PNE-
(Hz) Voltage
Amperes
(Volts)
(RLA)
018J*Z
1-60-208/230
9.0/9.0
024J*Z
1-60-208/230 12.5/12.5
030J*Z
1-60-208/230 18.1/18.1
036C*Z
3-60-208/230
42/42
036D*Z
3-60-460
6.9
036J*Z
1-60-208/230 20.5/20.5
042C*Z
3-60-208/230 14.4/14.4
042D*Z
3-60-460
7.4
042J*Z
1-60-208/230 22.7/22.7
048C*Z
3-60-208/230
15.1
048D*Z
3-60-460
7.7
048J*Z
1-60-208/230 23.4/23.4
048Y*Z➀
3-60-575
TBD
060C*Z
3-60-208/230 17.3/17.3
060D*Z
3-60-460
6.7
060J*Z
1-60-208/230 25.0/25.0
060Y*Z➀
3-60-575
TBD
➀ Electrical Data is not available at this time
TABLE 2
(-)PPC ELECTRICAL AND PHYSICAL DATA
Model
Compressor
Phase
Number
Frequency
Rated Load
(-)PPC-
(Hz) Voltage
Amperes
(Volts)
(RLA)
060JAZ
1-60-208-230
25/25
6
ELECTRICAL
Fan Motor
Minimum
Full Load
Circuit
Locked Rotor
Amperes
Ampacity
Amperes
(FLA)
Amperes
(LRA)
41
0.6
12/12
54
0.8
17/17
72.5
0.8
24/24
77
0.8
19/19
39
0.4
9
88
0.8
27/27
88
1.2
20/20
44
0.6
10
104
1.2
30/30
91
1.2
20/20
46
0.6
11
137
1.2
31/31
TBD
TBD
TBD
123
1.2
23/23
49.5
0.6
10
148
1.2
33/33
TBD
TBD
TBD
ELECTRICAL
Fan Motor
Minimum
Full Load
Circuit
Locked Rotor
Amperes
Ampacity
Amperes
(FLA)
Amperes
(LRA)
148
1.2
33/33

3.0 LOCATING UNIT

3.1 CORROSIVE ENVIRONMENT

The metal parts of this unit may be subject to rust or deterioration if exposed to a
corrosive environment. This oxidation could shorten the equipment's useful life.
Corrosive elements include, but are not limited to, salt spray, fog or mist in seacoast
areas, sulphur or chlorine from lawn watering systems, and various chemical conta-
minants from industries such as paper mills and petroleum refineries.
If the unit is to be installed in an area where contaminants are likely to be a prob-
lem, special attention should be given to the equipment location and exposure.
Avoid having lawn sprinkler heads spray directly on the unit cabinet.
In coastal areas, locate the unit on the side of the building away from the water-
front.
Shielding provided by a fence or shrubs may give some protection, but cannot
violate minimum airflow and service access clearances.
Elevating the unit off its slab or base enough to allow air circulation will help
avoid holding water against the basepan.
Regular maintenance will reduce the build-up of contaminants and help to protect
the unit's finish.
Fuse or HACR
Outdoor Coil
Circuit Breaker
Minimum
Maximum
Face Area
Amperes
Amperes
Sq. Ft. (m
2
)
15/15
20/20
11 [1.02]
20/20
25/25
12.94 [1.2]
30/30
40/40
20.13 [1.87]
25/25
30/30
23.01 [2.14]
15
15
23.01 [2.14]
35/35
45/45
23.01 [2.14]
25/25
30/30
23.01 [2.14]
15
15
23.01 [2.14]
40/40
50/50
23.01 [2.14]
25/25
35/35
23.01 [2.14]
15
15
23.01 [2.14]
40/40
50/50
23.01 [2.14]
TBD
TBD
23.01 [2.14]
30/30
40/40
23.01 [2.14]
15
15
23.01 [2.14]
40/40
50/50
23.01 [2.14]
TBD
TBD
23.01 [2.14]
Fuse or HACR
Outdoor Coil
Circuit Breaker
Minimum
Maximum
Face Area
Amperes
Amperes
Sq. Ft. (m
2
)
40/40
50/50
23.01 [2.14]
PHYSICAL
R22
Oz. [g]
No.
CFM [L/s]
Rows
1
1925 [908]
74 [2098]
130 [59]
1
2475 [1168] 90 [2552] 175 [79.4] 185 [83]
1
2650 [1251] 129 [3657] 200 [90.7] 210 [95]
1
3000 [1416] 139 [3941] 220 [99.8] 230 [104]
1
3000 [1416] 139 [3941] 220 [99.8] 230 [104]
1
3000 [1416] 139 [3941] 220 [99.8] 230 [104]
1
3575 [1687] 146 [4139] 230 [104.3] 240 [108]
1
3575 [1687] 146 [4139] 230 [104.3] 240 [108]
1
3575 [1687] 146 [4139] 230 [104.3] 240 [108]
1
3575 [1687] 155 [4394] 250 [113.4] 260 [117]
1
3575 [1687] 155 [4394] 250 [113.4] 260 [117]
1
3575 [1687] 155 [4394] 250 [113.4] 260 [117]
1
3575 [1687] 155 [4394] 250 [113.4] 260 [117]
2
3350 [1581] 306 [8675] 280 [127] 290 [131]
2
3350 [1581] 306 [8675] 280 [127] 290 [131]
2
3350 [1581] 306 [8675] 280 [127] 290 [131]
2
3350 [1581] 306 [8675] 280 [127] 290 [131]
PHYSICAL
Refrig.
Per
Circuit
No.
CFM [L/s]
Oz. [g]
Rows
Lbs. [kg]
2
3350 [1581] 295 [8363] 255 [115.7] 265 [120.2]
Weight
Net
Shipping
Oz. [g]
Lbs. [kg]
140 [63]
Weight
Net
Shipping
Lbs. [kg]