Hard Start Components; Time Delay Control (Tdc); Low Ambient Control (Lac); High Pressure Controls (Hpc) - Reelin PNE 13 Seer Installation Instructions Manual

Table of Contents

Advertisement

TABLE 9
MAXIMUM SYSTEM CHARGE VALUES: (-)PNE SINGLE PHASE
Model
Size*
-018
-024
-030
-036
-042
-048
*-060 comes with the crankcase heater factory-installed.
TABLE 10
MAXIMUM SYSTEM CHARGE VALUES: (-)PPC
Model
Size*
-018
-024
-030
-036
-042
-048
*-060 comes with crankcase heater factory-installed.
All heaters are located on the lower half of the compressor shell. Its purpose is to
drive refrigerant from the compressor shell during long off cycles, thus preventing
damage to the compressor during start-up.
At initial start-up or after extended shutdown periods, make sure the heater is ener-
gized for at least 12 hours before the compressor is started. (Disconnect switch on
and wall thermostat off.)

14.2 HARD START COMPONENTS

Start components are not usually required with the scroll compressors used in
(-)PNE heat pumps, but are available for special cases and where start components
are desirable to reduce light dimming.
NOTE: Hard start components are standard on (-)PNE/(-)PPC****AZ models.

14.3 TIME DELAY CONTROL (TDC)

The time delay (TDC) is in the low voltage control circuit. When the compressor
shuts off due to a power failure or thermostat operation, this control keeps it off at
least 5 minutes which allows the system pressure to equalize, thus not damaging
the compressor or blowing fuses on start-up.

14.4 LOW AMBIENT CONTROL (LAC)

This component senses compressor head pressure and shuts the heat pump fan off
when the head pressure drops to approximately 150 PSIG. This allows the unit to
build a sufficient head pressure at lower ambient in order to maintain system bal-
ance and obtain improved capacity. Low ambient control should be used on all
equipment operated below 65°F ambient.
14.5 HIGH PRESSURE CONTROL (HPC)
These controls keep the compressor from operating in pressure ranges which can
cause damage to the compressor. The HPC is in the low voltage control circuit.
High pressure control (HPC) is a manual reset which opens near 440 PSIG. Do not
reset arbitrarily without first determining what caused it to trip.
NOTE: High pressure control is standard on (-)PNE
14.6 ENHANCED COMPRESSOR PROTECTION KIT – RXPG-A01
This kit includes an enhanced defrost control, auto-reset high pressure control
(HPC), and an auto-reset low pressure control (LPC) that will convert the control
system of a (-)PNE-****BZ to the enhanced control system of a (-)PNE-****AZ. This
kit provides compressor protection under abnormally high head pressure conditions
(outdoor fan failure, restriction, dirty coil, etc.) or abnormally low suction pressure
conditions (restriction, TEV failure, loss of charge, indoor blower failure, etc.) while
eliminating nuisance tripping sometimes experienced with conventional control sys-
tems.
NOTE: This kit is not necessary on (-)PNE
standard from the factory with this control system.
Compressor
Model Number
ZR16K4-PFV
ZR22K3-PFV
ZR28K3-PFV
ZR34K3-PFV
ZR40K3-PFV
ZR45K3-PFV
Compressor
Model Number
TBD
TBD
TBD
TBD
TBD
TBD
/(-)PPC
/(-)PPC
****AZ models since they come
Charge Limit
Without
Crankcase Heater*
7.2 lbs.
9.6 lbs.
9.6 lbs.
9.6 lbs.
9.6 lbs.
9.6 lbs.
Charge Limit
Without
Crankcase Heater*
TBD
TBD
TBD
TBD
TBD
TBD
****AZ models.