Tubing Connections; Leak Testing - Reelin PNE 13 Seer Installation Instructions Manual

Table of Contents

Advertisement

TABLE 4
VAPOR LINE LENGTH SIZE AND CAPACITY MULTIPLIER
(-)PNE/(-)PPC
Unit Vapor Line
Connection Size
Vapor Line Run
- Feet
Opt.
25
Std.
Opt.
Opt.
50
Std.
Opt.
Opt.
100
Std.
Opt.
Opt.
150
Std.
Opt.
NOTES: 1) Capacity Multiplier x Rated Capacity = Actual Capacity. 2) Additional compressor oil is not required for runs up to 150 feet.
3) Oil traps in vertical runs are not required for any height up to 125 feet. See Liquid Line charts for Vertical Separation Requirements
and Limitations. 4) Adapter to 1-1/8 Factory Supplied.
12
018
024
3/4 L.D. Sweat
5/8 O.D. Optional
3/4 O.D. Optional
7/8 O.D. Optional
.98
.98
1.00
1.00
1.01
1.01
.96
.96
.99
.99
1.00
1.00
.93
.93
.99
.98
1.00
.99
.98
.97
1.00
.98

7.6 TUBING CONNECTIONS

Indoor coils have only a holding charge of dry nitrogen. Keep all tube ends sealed
until connections are to be made.
Use type "L" copper refrigeration tubing. Braze the connections with accepted
industry practices.
Be certain both refrigerant shutoff valves at the outdoor unit are closed.
Clean the inside of the fittings before brazing.
Remove the cap and schrader core from service port to protect seals from heat
damage.
Use an appropriate heatsink material around the copper stub and the service
valves before applying heat.
IMPORTANT: Do not braze any fitting with the TEV sensing bulb attached.
Braze the tubing between the outdoor unit and indoor coil. Flow dry nitrogen
into a service port and through the tubing while brazing.
The service valves are not backseating valves. To open the valves, remove the
valve cap with an adjustable wrench. Insert a 3/16" or 5/16" hex wrench into the
stem. Back out counterclockwise.
Replace the valve cap finger tight then tighten an additional 1/2 hex flat for a
metal-to-metal seal.

7.7 LEAK TESTING

Pressurize line set and coil through service fittings with dry nitrogen to 150
PSIG maximum. Leak test all joints using liquid detergent. If a leak is found,
relieve pressure and repair.
WARNING
!
Do not use oxygen to purge lines or pressurize system for leak test.
Oxygen reacts violently with oil, which can cause an explosion resulting in
severe personal injury or death.
030
036
7/8 L.D. Sweat
3/4 O.D. Optional
7/8 O.D. Optional
1-1/8 O.D. Optional
.98
.99
1.00
1.00
1.01
1.01
.96
.97
.99
.99
1.00
1.01
.97
.98
.99
1.00
.95
.97
.97
.99
042
048
1-1/8 L.D. Sweat (4)
7/8 O.D. Optional
1-1/8 O.D. Optional
1-3/8 O.D. Optional
.99
.99
1.00
1.00
1.01
1.01
.97
.97
.99
1.00
1.01
1.01
.96
.98
.99
1.00
1.00
.96
.99
.99
1.00
060
.99
1.00
1.01
.97
.99
1.01
.95
.99
1.00
.98
.99