Heritage Information
Quiet Times
Quiet time periods can be entered in hours to
prevent automatic operation of the generator
during inappropriate times. Hours may be set
for AM or PM. There are three quiet time peri-
ods that can be entered into the system. Each of
the three quiet time periods can be enabled (On)
or disabled (Off) independently. Please note,
12:00 AM is midnight and 12:00 PM is noon.
Total Time
The total time field displays the total accumu-
lated hours and minutes that the generator has
ran. This indicator is located at the top of the
generator screen.
Generator Status
The Generator Status field shows the run status
of the generator. This indicator is shown at the
bottom of the generator screen.
If
the generator
is running the Generator Status field will shows
the label "On."
It
the generator is stopped the
Generator Status field shows the label "Off."
Tank Levels Screen
The tank level screen displays the fluid level of
the fresh water, gray water, black water, and the
Propane. This screen also allows the user to set
warning set points for each of the corresponding
tanks.
The warning set points are modified by first
pressing the navigation field (located at the bot-
tom of the display screen between the arrow
buttons) until it's label shows "Select." Now use
the "down" or "up" arrow button to scroll down
or up until the "Warning Set Point field for the
desired line item is highlighted. Press the navi-
gation button until the label shows "Change."
Press any arrow button and observe that the per-
centage shown in the field changes. The selec-
tions for each set point is 0, 25, 50, 75, 100, and
NONE. NONE is used to disable that line item
from issuing a warning. Once the desired set
point is displayed in the field, press the naviga-
tion field until the label shows "Select." At this
point you can now move to another set point
with the arrow buttons or move to the "Exit." To
exit, use the arrow keys to highlight the "Exit"
field. Press the navigation button until the label
shows "Menu."
Figure 6 - Tank Levels Screen
AC Power Screen
The AC Power Screen shown in Figure 7 A
provides the user with information related to the
AC power supplied to the coach either from an
external source or from the on-board generator.
The display provides the source that power is
currently connected to (Generator, Shore or
None) along with the voltage of each leg,
amperage of each leg, and frequency. In
addition a reminder is provided to the owner
when Bypass mode has been activated.
The system also has the ability to detect certain
faults or bad power conditions. When the
system detects that a monitored fault has
occurred, a button will appear on the AC Power
Screen labeled "View Faults". Pressing this
button will cause the AC Power Fault Screen
of Figurer 7B to be displayed. This "Fault"
screen will provide fault status and if service of
the Transfer Box is required. From the AC
Power Fault Screen, pressing the button
"Return" will return the user to the AC Power
Screen shown in Figure 7 A.