Easy Connect (EZConnect™) INSTRUCTIONS
EZConnect Installation
1. EZConnect allows the installation of two Water Heater units together utilizing the EZConnect
cord.
2. Install the two Water Heater units 2" ~ 18" apart so that the cord will be able to reach between
two units.
3. Do not install more than 18" apart between two water heaters. To do so, will cause temperature
fluctuations (cold water sandwich effect) whereby the water is shut off, then turned on again.
4. The EZConnect shall be disabled before installing with the MSA controller system.
Recommended Installation Layout:
Fig.1
Remove this
protective
Cap
Plug in
Fig.2
5. Before installing the EZConnect cord, remove the protective cap from the 3 pin connector
marked "EZConnect" located in the wiring harness of the Primary Unit. (Fig.1)
6. To install the EZConnect cord, plug in the cord on both the
Sub unit and Primary unit accordingly – see installation layout
above. (Fig.2,3)
7. Securely tighten the EZConnect cord to the bottom of Water
Heater by using Cable Clamp and Screw supplied. (Fig.4)
(Both of Primary and Sub Unit)
Rinnai Corporation
Primary Unit
Temperature settings can only be changed on the primary unit controller.
This system can not use the bathfill function.
(REU-EZC-1US)
Sub Unit
2~18"
PCB
38
Fig.3
PCB
Tighten the EZConnect cord
EZConnect Cable
Cable Clamp(Supplied)
Screw(Supplied)
V3237 Models
Fig.4

Hide quick links: