Operating Logic; Instructions For Settings And Operation; Temperature Adjustment; Compressor Operation - Indesit New electronic cold platform 2005 Service Manual

Refrigerator
Table of Contents

Advertisement

2. PRODUCT TYPE:
NO FROST FRIDGE-FREEZER AND ELECTRONIC THERMOSTAT DOUBLE DOOR.
The user interface is located on the fridge cabi-
net in Fridge-Freezer models and on the freezer
cabinet in Double Door models.
SWITCHING THE APPLIANCE OFF AND ON:
The appliance is switched Off when the knob is set
to Minimum. To switch on the appliance turn the knob
clockwise away from the Minimum position (appli-
ance OFF). Turn the knob counterclockwise to the
Minimum position to switch off the appliance.

TEMPERATURE ADJUSTMENT:

The freezer compartment temperature is adjusted
by the electronic PCB. To set a lower temperature
tur n the knob clockwise, turning the knob
counterclockwise gives a higher temperature. The
refrigerator compartment temperature depends on
the adjustment of the freezer compartment tempera-

COMPRESSOR OPERATION:

The compressor serves to compress the gas in the
thermodynamic circuit in order to generate the nec-
essary cooling capacity to chill the appliance com-
partments.
The compressor is managed by the Main PCB with
the aid of a relay and a triac that trips, in parallel
with the relay, only at the time of compressor power-
on and power-off to protect the relay from electrical
arcing when the contact is opened and closed. The
compressor
Service Manual
New Electronic Cold Platform 2005
ture. The refrigerator compartment temperature is
controlled by a mechanical damper located on the
multiflow unit. The damper enables cold air from the
evaporator coil to cool the refrigerator compartment.
Temperature adjustment is performed in accordance
with specific rules if the following conditions occur:
• Temperature detected by PCB sensor (on the
board) is between two values parameterised in
the EEPROM memory;
• The time that has elapsed from the last time the
door was opened is greater than the relative pa-
rameter stored in the EEPROM memory;
• The compressor power-on time is lower than the
parameter stored in the EEPROM;