5.5. TROUBLESHOOTING:

PROBLEM
Fails to switch on.
Compressor fails to start
Compressor runs but ap-
pliance fails to cool.
Compressor unable to
start.
Water under crisper draw-
ers.
Water on floor.
Compressor fails to stop.
Compressor fails to start.
Door open alarm sounds
continuously.
Display switches off in-
termittently.
For No-Frost appliances:
the compartments are in-
sufficiently cold.
For No-Frost appliances: the
refrigerator compartment
does not cool properly.
Refrigerator compartment too
cold - food tends to freeze.
Service Manual
New Electronic Cold Platform 2005
- Check voltage on socket outlet.
- Check power cord.
- Check continuity of windings
- Check operation of Klixon relay.
- Faulty PCB.
- Appliance set to OFF.
- Compressor is cold - check refrigerant charge.
- Compressor is very hot - Check for traces of oil or refrigerant circuit is
blocked.
- Check for possible faulty compressor.
- Faulty Klixon relay.
- Faulty compressor.
- Mains voltage very low.
- Drain hole blocked.
- Container or wrapping paper touching refrigeration wall.
- Condensate collection bowl broken.
- Water drain tube incorrectly positioned.
- Condensate collection bowl not in contact with compressor.
- Faulty thermostat.
- Incorrectly positioned thermostat.
- Unsuitable installation on electrical Klixon.
- Door fails to close properly.
- Refrigerant circuit insufficient charge or blocked.
- Damaged compressor.
- Check Thermostat/PCB.
- No magnet in door.
- Faulty PCB.
- Door is distorted.
- Check display cable.
- Check display PCB.
- Evaporator coil clogged with ice.
- Check fusible link.
- Check heating elements.
- Chilled air suction fan motor.
- Ice has formed in the duct between the refrigerator and freezer compartments.
- Check temperature sensors.