APPLIANCE THERMODYNAMICS:
Interior chilling performance of new No-Frost appliance:
The refrigeration system of the new no frost refrigerator consists of a cooling circuit whose main elements
are a vertical finned evaporator (Fig 1) and a fan located in the freezer compartment(behind the com-
partments partition - Fig. 2).partments partition - Fig. 2).
Fridge Air
Delivery
vent
Drip tray
(Fig 1)
The cold air that flows through the evaporator coil is routed to the Refrigerator compartment (Fig 3) and the
freezer compartment (Fig 2) thereby causing the required cooling effect.
Electronic Damper
(cold air inlet to
fridge)
Fridge Air
Return vent
(Fig 3)
Service Manual
New Electronic Cold Platform 2005
Position of
defrost
end sensor
Position of
double
fusible link
Fridge Air
Return
Vent
Position of
Freezer Air
sensor
Edition
2005.03.25
Position of Fridge Air
Sensor
Language
English
G
B
(Fig 2)