Amerec AK Series Installation And Service Instructions Manual

Amerec AK Series Installation And Service Instructions Manual

Steambath generators 230-400v
Hide thumbs Also See for AK Series:

Advertisement

Possible Controls
K60/KT60
OR
K30
OR
R30K
AMEREC STEAMBATH GENERATORS
(AK and 3K MODELS) 230-400V
Note:To be used with the K30,K60,KT60 or R30K Control.

SAVE THESE INSTRUCTIONS

READ ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLATION.
POST "WARNING" LABEL OUTSIDE STEAMBATH FOR SAFETY
WARNINGS. REQUIRED POSTING ON DOOR OF STEAM ROOM
OR ADJACENT TO DOOR FOR ALL COMMERCIAL
INSTALLATIONS.
SECTION 1: GENERAL INFORMATION
The AMEREC steam generators come assembled and ready for installation. Check that the size and rating of
the generator is suitable for your application, refer to Steam Room Construction and Generator Sizing Guide
(AMEREC document 4211-38).
IMPORTANT
An exhaust fan installed outside the steam
room is strongly recommended to remove
excess steam from the bathroom or shower
area.
4211-139-A
08-14-2009
AK and 3K Series Installation and Service
Instructions
AK GENERATOR
WARNING
Electrical grounding is required on
all AMEREC Steambath Generators.
All electrical supplies should be
disconnected when servicing
generator.
All wiring must be installed by a
licensed electrical contractor in
accordance with local and national
codes.
All plumbing must be installed by a
licensed plumber in accordance with
all applicable local and national
codes.
AK series generators are for indoor
use only.
AK series generators are not for
space heating purposes.
Be certain that steambath enclosures
are properly sealed to avoid water
damage from escaping steam. It is
recommended that 100% silicone
caulk be used to seal all pipes and
fittings. Steam must be prevented
from escaping into the wall cavity.
Never shut off the water to a steam
generator that is in use.
Electric Shock Hazard - High voltage
exists within this equipment. There
are no user serviceable parts in this
equipment.
WARNING
REDUCE THE RISK OF
OVERHEATING AND SCALDING
1. Exit immediately if uncomfortable, dizzy or sleepy. Staying too long in
a heated area is capable of causing overheating.
2. Supervise children at all times.
3. Check with a doctor before use if pregnant, diabetic, in poor health or
under medical care.
4. Breathing heated air in conjunction with consumption of alcohol, drugs
or medication is capable of causing unconsciousness.
Do not contact steam head. Stay at least 12" away
CAUTION!
from hot steam escaping from the steam outlet.
REDUCE THE RISK OF
SLIPPING AND FALL INJURY
Use care when entering or exiting the steam room, floor may be slippery.
NOTE: For additional safety instructions, see owner's manual.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AK Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Amerec AK Series

  • Page 1: Save These Instructions

    REDUCE THE RISK OF SLIPPING AND FALL INJURY The AMEREC steam generators come assembled and ready for installation. Check that the size and rating of Use care when entering or exiting the steam room, floor may be slippery. the generator is suitable for your application, refer to Steam Room Construction and Generator Sizing Guide NOTE: For additional safety instructions, see owner’s manual.
  • Page 2: Table Of Contents

    AK and 3K Series Installation and Service Instructions page 2 Table of Contents Section Description Page Important Safety Instructions Select Mounting Location Mounting the Generator Water Quality Requirements Plumbing Instructions Wiring Instructions Electrical Information Chart Operational Test Service 9-11 Optional Modifications Trouble Shooting 12-13 Exploded Parts Diagram...
  • Page 3 AK and 3K Series Installation and Service Instructions page 3 IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS 2. WARNING - To reduce the risk of injury, do not permit children to use this product unless they are closely supervised at all times. 3.
  • Page 4 AK and 3K Series Installation and Service Instructions page 4 DIAGRAM 1 DIAGRAM 2 WATER SHUT-OFF VALVE 9,5 mm 1/2" NPT FITTING FROM WALL OPTIONAL FILTER 3/8" COMPRESSION DO NOT CONNECT TO WATER ADAPTER SUPPLY WITH SADDLE FITTING 1/2" STEAM LINE TO ROOM 1/2"...
  • Page 5: Select Mounting Location

    WARNING SECTION 2: SELECT MOUNTING LOCATION SEE DIAGRAMS The AMEREC steam generator can be hung on a wall 4. The generator should be installed in a dry, well Do not mount outdoors. or sit on its base. The best mounting location will ventilated area.
  • Page 6 AK and 3K Series Installation and Service Instructions page 6 DIAGRAM 5 DIAGRAM 6 9,5 mm FROM WALL 1/2" NPT FITTING 35 mm 0,6 mm DIAMETER HOLE STEAM HEAD INSULATOR 1/2" NPT SWEAT ADAPTER FRAGRANCE RESERVOIR CENTER IN OPENING 0,6 mm 35 mm DIAMETER HOLE ESCUTCHEON STEAM HEAD...
  • Page 7: Plumbing Instructions

    AK and 3K Series Installation and Service Instructions page 7 SECTION 5: PLUMBING INSTRUCTIONS WARNING SEE DIAGRAMS Do not connect the overpressure All plumbing shall be installed by a licensed plumber device output into the steam line. IMPORTANT and conform with local & national codes. If the steam line is in an area where the temperature will be below 4°C or if the line Materials (locally available):...
  • Page 8: Wiring Instructions

    AK and 3K Series Installation and Service Instructions page 8 SECTION 6: WIRING INSTRUCTIONS WARNING SEE ELEC. INFO. CHART AND WIRING DIAGRAM 5. INSTALL GENERATOR CONTROL (K30,K60,KT60) 1. CONTROL CABLE ROUGH-IN The pressure relief valve must be The low voltage controls can be mounted directly to The low voltage control can be mounted up to 7,6 M a finished wall either inside or outside the steam installed in such a fashion that the...
  • Page 9: Electrical Information Chart

    AK and 3K Series Installation and Service Instructions page 9 DIAGRAM 12 DIAGRAM 11 USED WITH K60 OR K30 CONTROL ONLY WALL SILICONE WALL CAULK DECORATIVE TEMPERATURE CONTROL COVER SENSOR PLATE (BUILT-IN SENSOR ON KT60 CONTROL ONLY) PROBE MUST BE POINTED PIGTAIL SENSOR DOWN...
  • Page 10: Operational Test

    All wiring should be - VISUAL INSPECTION - Whenever the generator is The AK series is one of AMEREC’s high performance opened, inspect for any evidence of water leaks. line of steam generator products.
  • Page 11 AK and 3K Series Installation and Service Instructions page 11 DIAGRAM 15 DIAGRAM 16 DIAGRAM 17 VERTICAL ± 15° ELEMENT END ORIENTATION RUBBER GASKET LEVEL PROBE 3 to 9,5 mm GASKET HEAT ELEMENT DIAGRAM 18 DIAGRAM 19 NOTE TAB OFFSET IN This diagram intentionally left blank.
  • Page 12: Service

    Disconnect power from the unit. Turn the water disconnected when servicing supply OFF. Disconnect the water supply from the generator. 3. REPAIR OF AK SERIES GENERATORS water solenoid valve. Remove the front cover. Re- A. ELEMENT REPLACEMENT: move the two blue wires from the water solenoid Disconnect power from the unit.
  • Page 13: Optional Modifications

    There are no user serviceable parts in the Generator. All repair should be performed by a qualified service person. For additional assistance or the factory authorized service person nearest you call the AMEREC Service Department at 1-800-331-0349. The Trouble Shooting Guide below is meant as a general aid only. Follow ACTION TO BE TAKEN in order until the problem is resolved.
  • Page 14 3. Replace sensor and/or cable - call AMEREC's Service Department. Control "ON". Steambath temperature over 55° C 1. If bath is too hot, shut off circuit breaker and call AMEREC's Service K60/KT60 Control displays Department. ">>>º" Sensor/cable faulty.
  • Page 15 AK and 3K Series Installation and Service Instructions page 15 4211-139-A 08-14-2009...
  • Page 16 CHASSIS TERMINAL POWER INPUT TERMINAL BLOCK • For assistance or parts ordering, COVER FRONT WITH WD LABEL please contact your local AMEREC COVER ELEMENT ACCESS Dealer or AMEREC at 1-800-331-0349. Please help us to serve you better by: TANK ELEMENTS...
  • Page 17 AK and 3K Series Installation and Service Instructions page 17 4211-139-A 08-14-2009...
  • Page 18 AK and 3K Series Installation and Service Instructions page 18 4211-139-A 08-14-2009...
  • Page 19 AK and 3K Series Installation and Service Instructions page 19 P.O. Box 2258, Woodinville WA 98072 425-951-1120 Fax: 425-951-1130 email address: amerec @ amerec .com 4211-139-A 08-14-2009...