20. Adjust with the
key (adjusted value up) or
key (adjusted value down) so that the adjusted value becomes
20.
This set LCD display
0 23
20: Adjusted value
21. Press the
key.
X
(0D5F is blinking)
[VOL+]
22. Press the
key once to change the blinking portion to
0D60.
This set LCD display
0 23
00: Adjusted value
23. Press the
x
key.
(00 is blinking)
[VOL+]
24. Adjust with the
key (adjusted value up) or
key (adjusted value down) so that the adjusted value becomes
08.
This set LCD display
0 23
08: Adjusted value
25. Press the
key.
X
(0D60 is blinking)
[VOL+]
26. Press the
key once to change the blinking portion to
0D61.
This set LCD display
0 23
00: Adjusted value
27. Press the
x
key.
(00 is blinking)
[VOL+]
28. Adjust with the
key (adjusted value up) or
key (adjusted value down) so that the adjusted value becomes
A1.
This set LCD display
0 23
A1: Adjusted value
29. Press the
key.
X
(0D61 is blinking)
[VOL+]
30. Press the
key once to change the blinking portion to
0D62.
This set LCD display
0 23
00: Adjusted value
[VOL--]
0D5F20
0D6000
[VOL--]
0D6008
0D6100
[VOL--]
0D61A1
0D6200
31. Press the
key.
x
(00 is blinking)
[VOL+]
32. Adjust with the
key (adjusted value up) or
key (adjusted value down) so that the adjusted value becomes
04.
This set LCD display
0 2 3
04: Adjusted value
33. Press the
X
key.
(0D62 is blinking)
[VOL+]
34. Press the
key once to change the blinking portion to
0D65.
This set LCD display
0 2 3
00: Adjusted value
35. Press the
key.
x
(00 is blinking)
[VOL+]
36. Adjust with the
key (adjusted value up) or
key (adjusted value down) so that the adjusted value becomes
20.
This set LCD display
0 2 3
20: Adjusted value
37. Press the
X
key.
(0D65 is blinking)
[T.MARK]
38. Press the
key for several seconds (about 3 seconds)
to exit the patch data write mode (to return to the manual mode
display in the test mode).
This set LCD display
0 2 3
[ENTER]
39. Press the
key and set the address & adjusted value
display (see page 14).
This set LCD display
0 2 3
01: Adjusted value
40. Press the
key to write the modified data. (The adjusted value
X
changes to CC)
41. The modified data writing is over, if the adjusted value changes
to DD.
This set LCD display
0 2 3
DD: Adjusted value
42. Turn the power off.
MZ-R500/R500PC
[VOL--]
0D6204
0D6500
[VOL--]
0D6520
Patch