H
R
ARD
ESET
Should the console memory become corrupted it can be
reset to the factory defaults by performing a hard reset :
Hold down EDIT GROUP + PREVIEW GROUP while
powering up the console. The following condition set :
All console mutes turned on.
Patch display shows
All mute patches cleared (mutes turned off).
All mute groups cleared (mutes turned off).
MIDI channel set to 16.
No mute safes set.
No solo safes set.
E
M
RROR
ESSAGES
In the event of an automation error an error message is
displayed. This is a two part message comprising an error
number and an error code. For example, should a MIDI
Dump In error be detected the following error number will
be displayed :
En0
Press any automation key to show the error code which
gives further information about the error.
Ec1
Press any automation key to clear the error display and
return the system to normal operation.
The following ERROR MESSAGES apply :
NUMBER
CODE
0
0
1
2
3
4
1
0
1
2
3
4
2
0
DESCRIPTION
MIDI Dump In error
Packet 0 not received
Missing packet
Buffer overflow
Checksum error
Dump timeout
EEPROM memory access error
Write error
Page write error
Read error
Page read error
Byte read error
Power brown-out detected