Condensing Unit - Breezaire WKS-2200 Series Installation Instructions Manual

Advertisement

110 VOLTS
WARNING: THE COMPLETED SYSTEM MUST BE PRESSURED TESTED FOR A MINIMUM OF 6
HOURS AND THEN EVACUATED TO HOLD A 250 MICRON VACUUM FOR A MINIMUM OF 15
MINUTES. ANY LEAKS DISCOVERED AFTER REFRIGERANT CHARGING ARE THE SOLE
On initial start-up the cooling unit will reduce the temperature of the enclosure slowly. The unit may run constantly or cycle
off for short periods. The time required to reach the desired temperature will vary, depending on the enclosure's construction
and contents. The thermostat is factory set to approximately 55 o F. Unless the temperature falls below what is desired, do
not change the thermostat setting for at least 3 days. After initial cool down, the "on-off" cycle should be relatively constant.
The percentage of "off " time will depend on enclosure's construction, contents, and surrounding outside temperatures.
The BREEZAIRE cooling unit requires very little maintenance. At least once every three months the condenser coil should
be inspected and vacuumed to prevent any air blockage. The condenser coil, in the condensing unit is located out side the
enclosure. Use a vacuum and brush attachment to remove the lint or dirt that may reside between the aluminum fins. If the
condenser coil becomes blocked preventing proper air flow the unit will over heat causing a loss in cooling
efficiency and will result in failure of the unit not covered under warranty.
BREEZAIRE is extremely proud of the quality and reliability of its products. Experience has shown that of the small
number of problems encountered, the large majority are due to improper unit selection or enclosure construction. Should the
cooling system be suspected of malfunctioning, check the temperature of the air being exhausted from the condenser's
exhaust grille. If it is warm, the unit is working. A further check may be made by comparing the air temperature entering
the lower grille on the fan/coil unit with that leaving the top smaller grille. If the air leaving the unit is at least 6 o F less than
the temperature entering, the unit is working properly.
THERMOSTAT
EVAP FANS
FAN / COIL
RESPONSIBILITY OF THE INSTALLER.
ENCLOSURE PROBLEMS
COND FANS

CONDENSING UNIT

GROUNDS NOT SHOWN
OPERATION
MAINTENANCE
WKS2200 2/04 PG4