While great effort has been made to provide accurate guidelines,
construction, unit location and many other factors can affect the operation and performance of the unit. Therefore the suitability of the unit for a specific enclosure or application must
be determined by the customer and cannot be warranted by
BREEZAIRE Products Company - 8610 Production Avenue - San Diego, CA USA 92121 - (858) 566-7465
WKS 2200 SERIES
(USA only)
BREEZAIRE
cannot warrant its units to properly cool a particular enclosure. Customers are cautioned that enclosure
8610 Production Avenue l San Diego, California 92121 l (858) 566-7465 l Fax (858) 566-1943 l WWW.BREEZAIRE.COM --INSTALLATION INSTRUCTIONS-- Thank you for choosing a BREEZAIRE cooling unit. We believe our products are the best on the market and will provide many years of trouble free service.
Page 2
FOR WKS 2200 SERIES COOLING UNITS The BREEZAIRE WK Series cooling units are designed to, when installed in a properly constructed enclosure, provide a constant, selectable temperature between 48°F and 62°F while reducing the excess relative humidity to the proper 50% to 75%.
BREEZAIRE recommends the use of a licensed refrigeration technician to install the WKS systems. Installation of the unit's line set through a fire rated wall must be done in accordance with your local building inspector and building codes. F If your installation cannot be performed in accordance with these instructions contact your dealer.
110 VOLTS FAN COIL = WHITE (COMMON) HOURS AND THEN EVACUATED TO HOLD A 250 MICRON VACUUM FOR A MINIMUM OF 15 MINUTES. (NOTE: THIS SHOULD TAKE ABOUT 6 HRS TO ACHIEVE) ANY LEAKS DISCOVERED AFTER REFRIGERANT CHARGING ARE THE SOLE RESPONSIBILITY OF THE INSTALLER. F Charging the system: After all components have been connected, pressure test the complete system for a minimum of six hours.
ENCLOSURE PROBLEMS BREEZAIRE is extremely proud of the quality and reliability of its products. Experience has shown that of the small number of problems encountered, the large majority are due to improper unit selection or enclosure construction. Should the cooling system be suspected of malfunctioning, check the temperature of the air being exhausted from the condenser outlet.
Page 6
THERMOSTAT 3/8" OD DRAIN TUBE 1/4" LIQUID LINE 3/8" SUCTION LINE 110V ELECTRICAL CORD FAN/COIL UNIT CONDENSER OUTLET CONDENSING UNIT BREEZAIRE Models WKS 2200 Fan/Coil (Figure 1) WKS 2200 Condenser (Figure 2) EVAPORATOR INTAKE EVAPORATOR OUTLET FIGURE 1 CONDENSER INTAKE 3/8"...