Enclosure Construction - Breezaire WKS-2200 Series Installation Instructions Manual

Advertisement

The BREEZAIRE WKS Series cooling units will provide a stable temperature when installed in a properly constructed
enclosure, provide constant cooling, temperature between 50 o and 62 o Fahrenheit, while reducing excess moisture. In a
properly constructed enclosure this cooling process may raise the relative humidity to the proper 50% to 70%. The unit
does not add moisture to the enclosure. The unit does not include a heating system and will not warm the enclosure. The
WKS Series is not intended to cool service cabinets which are maintained at lower temperatures and/or opened frequently.
The WKS Series cooling unit, is shipped as components, not a working cooling system. Only after a qualified refrigeration
installer has properly connected these components, pressured tested, evacuated, charged with refrigerant and tested their
installation, can the unit be considered a cooling system. Proper installation is critical to the performance, reliability and
longevity of the system. For this reason, BREEZAIRE can only warrant the quality of the WKS components. The
installation and proper operation must be warranted by the installer. Before installation is to begin, the purchaser and
installer should carefully read the enclosed Limited Warranty.
To use the below SIZING GUIDE, the enclosure to be cooled must be built to the following minimum specifications. If the
enclosure is not built to these specifications, consult your BREEZAIRE dealer for assistance in choosing the correct unit.
BREEZAIRE units are not warranted to cool a specific enclosure.
All interior walls and floor should have a vapor barrier and a minimum of R-11 insulation. All exterior wall's insulation values
should be a minimum of R-19. The ceiling should have vapor barrier and a minimum of R-19 insulation. The vapor barrier
should be installed on the warm side of the insulation. There should be no glass windows or doors.
F
All joints, door frames, electrical outlets or switches and any pipes or vents which go through the enclosure should be
sealed to prevent air and moisture leakage into the room. Concrete, rock and brick are not insulation or moisture
barriers.
F
Doors into the enclosure should be of minimum size, insulated to R-11 and be tightly sealed with a high quality
weather stripping. Be sure to seal the bottom of the door and the fill gap between the door's frame and wall before
installing the cap molding.
F
Enclosure lighting should be of low wattage, with a timer to insure lights are not left on when the enclosure is
unoccupied.
Recessed
F
The ambient temperature surrounding the enclosure should not exceed the desired cellar's temperature by more than
25°. No enclosure wall should receive direct sunlight or strong wind.
BREEZAIRE Model
WKS2200 Fan/Coil
WKS2200 Condenser
This guide is to be used only for enclosures meeting the above construction requirements. Note: All units are 115 Volt, 60 Hz
INSTALLATION INSTRUCTIONS
FOR WKS2200 SERIES COOLING UNITS

ENCLOSURE CONSTRUCTION

lighting should not be used as they will allow outside air to enter the enclosure.
SIZING GUIDE & SPECIFICATIONS
Enclosure Volume
Electrical
265 cu.ft.
WKS2200 2/04 PG2
Dimensions (inches)
1 Amp
22w x 11h x 8d
4 Amps
14w x 10h x 12d
(lbs)
Weight
25
35