Samsung CKF5607L Service Manual page 24

Color monitor
Table of Contents

Advertisement

6 Alignment and Adjustments
6-4 Convergence Adjustments
Misconvergence occurs when one or more of the electron beams in a multibeam CRT fail to meet the
other beams at a specified point.
Table 6-4. Misconvergence Tolerances
Position
Error in mm
Center (A)
0.30
Edge (B)
0.40
1
11
Toshiba CRT
1 Setup Bolt
2 Bow Magnet
5 Band
6 6-Pole Magnet
9 Holder
10 Band
Figure 6-11. Toshiba Magnet Configuration
B
200 MM
Figure 6-12. Convergence Measurement Areas
6-8
CRT Dot Pitch
0.28
0.28
CRT
FRONT
2
10
3
4
5
6
7
8
9
3 Spacer
4 2-Pole Magnet
7 Spacer
8 4-Pole Magnet
11 Tabs
A
267 MM
6-4-1 Static (Center) Convergence
Static convergence involves alignment of the red,
blue and green lines in the center area of the
display. See "Dynamic Convergence" for
alignment of the color fields around the edges of
the display.
CONDITIONS
Direction:
Monitor facing east
Warm-up:
30 minutes
Display image: Crosshatch pattern
Tolerances:
See Table 6-4
PROCEDURE
As shown in Figure 6-11, the CRT used in these
monitors has the same magnet configuration as
shown in Table 6-5 below.
Table 6-5. Magnet Order
CRT Manufacturer
Magnet Order from Front of CRT
Toshiba
Convergence bow, 2-pole,
6-pole, 4-pole
Use the following steps to correct any static
misconvergence:
1. Make sure the display is not affected by
external magnetic fields.
2. Locate the pair of 4-pole magnet rings.
3. Unlock the rings and rotate the individual
rings (change the spacing between tabs) to
converge the vertical red and blue lines.
4. Rotate the pair of rings (maintaining the
spacing between tabs) to converge the
horizontal red and blue lines.
CKF5607L

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Syncmaster 500b plus ckf5607lSyncmaster 500b plus

Table of Contents