2.5

IECEx Conditions of Certification:

The enclosure is non-conducting and the area of the non-conducting part exceeds the maximum
permissible areas for Zone 0, Gb according to IEC 60079-0. Therefore when it is used within a
potentially explosive atmosphere, appropriate measures must be taken to prevent electrostatic
discharge.
2.6

ATEX Conditions for Safe Use:

The enclosure is non-conducting and the area of the non-conducting part exceeds the maximum
permissible areas for Category II 1 G (Zone 0) Gb according to EN 60079-0. Therefore when it is
used within a potentially explosive atmosphere, appropriate measures must be taken to prevent
electrostatic discharge.
Rev. 2
July 2011
OWA 100 Adapter User Manual
2. Specifications
2.5. IECEx Conditions of Certification:
9