9. Initial Defrosting
INPUT
1. D-Sensor
2. Initial Power Supply
1. Defrosting mode starts when D-Sensor [ 3.5 BC at initial power supply.
(It starts from Pre-cool.)
10. Explanation after Delivery
INPUT
1. TEMP Control Button
2. Power Cord
1. Start : push the TEMP Control Button for 5 seconds within 10sec
after initial power supply(plug-in).
2. Electric devices turn Off for 3 hours.
3. Display works in normal way.
11. Prevention of COMP Restart
INPUT
1. (None)
1. COMP does not restart for 6 minutes after COMP Off, though R-Sensor
turns On.
12. Buzzer Alarm
INPUT
1. Buttons on F-PCB
2. Door Switch
1. Buzzer rings by pushing F-PCB Buttons.
2. Buzzer rings for 1 second after initial power supply (plug-in).
3. Buzzer rings for 1 second at the start of A/S Forced Defrosting.
4. Buzzer rings every 1 minute after door opening.
(It rings within 5minutes and ring-time is prolonged as time passes.)
5. Buzzer makes short ring every 5 seconds in Error Display.
1. Defrosting Mode
CONTENTS
1. Electric Devices
CONTENTS
1. COMP
CONTENTS
1. BUZZER
CONTENTS
21
OPERATION AND FUNCTION
CONTROL OBJECT
COMP delayed for
6min. at initial
defrosting
CONTROL OBJECT
CONTROL OBJECT
6 min. delay
CONTROL OBJECT
REMARK
REMARK
REMARK
REMARK