Coleman 36ECMII Installation Instructions Manual

36” circulating louvered firebox

Advertisement

This book is valuable. In addition to instructing you on how to install and maintain your appliance, it also contains information that will
enable you to obtain replacement parts or optional accessory items when needed. Keep it with your other important papers.
WARNING:
ALWAYS
DOORS FULLY OPENED OR FULLY CLOSED
WHEN OPERATING THIS FIREPLACE.
This fireplace is approved for use as a wood burning fireplace or for use with a vented gas log approved to ANS Z21.60, Z21.84 or
RGA 2-72 standards or for use with a vent-free gas log heater approved to ANS Z21.11.2 standard. A vent-free log can only be
installed in an aftermarket (completion of sale, not for purpose of resale from the manufacturer), permanently located, manufactured
(mobile) home, where not prohibited by local codes. A DESA hood must be installed when using a vent-free gas log heater (see
Accessories, p. 11)
ALL DIMENSIONS IN THIS MANUAL ARE IN
INCHES UNLESS OTHERWISE SPECIFIED
DESA INTERNATIONAL
2701 INDUSTRIAL DRIVE
P.O. BOX 90024
BOWLING GREEN, KY 42102-9004
www.desatech.com
Includes: Manual Variable Control Fan System, Combustion

INSTALLATION INSTRUCTIONS

SAVE THIS BOOK
LEAVE
GLASS
This firebox meets the construction and safety standards of H.U.D. for
application in mobile homes when installed according to these instructions.
36" Circulating Louvered Firebox
Air Kit and Bi-Fold Doors with Brushed Brass finish
36ECMII
PN 54024
REV F
6/02

Advertisement

Table of Contents
loading

Summary of Contents for Coleman 36ECMII

  • Page 1: Installation Instructions

    36ECMII 36” Circulating Louvered Firebox Includes: Manual Variable Control Fan System, Combustion Air Kit and Bi-Fold Doors with Brushed Brass finish INSTALLATION INSTRUCTIONS SAVE THIS BOOK This book is valuable. In addition to instructing you on how to install and maintain your appliance, it also contains information that will enable you to obtain replacement parts or optional accessory items when needed.
  • Page 2: Table Of Contents

    CONTENTS INTRODUCTION --------------------------------------------------------------------------------- PG. 2 SELECTING LOCATION --------------------------------------------------------------------------------- PG. 2 3. MINIMUM CLEARANCES --------------------------------------------------------------------------------- PG. 2 4. FRAMING AND INSTALLING --------------------------------------------------------------------------------- PG. 3 5. HEARTH EXTENSION --------------------------------------------------------------------------------- PG. 3 6. OUTSIDE AIR KIT INSTALLATION --------------------------------------------------------------------------------- PG. 4 7. FAN KIT ASSEMBLY --------------------------------------------------------------------------------- PG.
  • Page 3: Introduction

    INTRODUCTION 4. An outside air kit is included with this fireplace. For Model 36ECMII is specifically designed for use in more details refer to section on outside air kit installation manufactured mobile homes. This fireplace includes a manual on page 4.
  • Page 4: Framing And Installing

    FRAMING AND INSTALLING THE FIREPLACE example, if the material selected has a K factor of 0.25, such STEP 1: Frame the opening for the fireplace using the as glass fiber, the following formula would apply. 0.25/0.84 x dimensions shown in figure 1 or 2. 1.0”...
  • Page 5: Outside Air Kit Installation

    FAN KIT ASSEMBLY (BK3) A fan kit assembly is preinstalled in this fireplace. Use of blowers or fans other than manufactured by DESA voids the warranty. The fan is operated by pressing the rocker switch located at the lower right hand corner of the fireplace face. Fan kit electrical connections are made through the electrical cover plate located on the side of the fireplace as shown in figure 6.
  • Page 6 ADJUSTABLE FIRESTOP THIMBLE (FST-A): If the adapter is needed, secure it onto the firestop using holes The Adjustable Firestop Thimble Assembly (FST-A) is used provided (see figure 10). The row of holes on the sides of the to provide the necessary air space and clearance between the thimble is provided to allow for pitch variances.
  • Page 7: Terminations

    FLASHING INSTALLATION: (V6F-8DM or V12F-8DM) IMPORTANT: Terminations are required but can be installed Determine the flashing to be used with the roof-opening chart. once the manufactured house is sited. Slide flashing over pipe until base is flat against roof. Replace as many shingles as needed to cover exposed area and flashing base.
  • Page 8: Finishing Your Fireplace

    GLASS DOORS 10 feet (see figure 16). Glass doors are standard with the 36ECMII fireplace. When the fireplace is in operation doors must be in the FULLY OPEN or FULLY CLOSED position only or a fire hazard may be created (see figure 18).
  • Page 9: Gas Line Installations

    FOR PERMANENTLY LOCATED (SITED) HOMES A vent-free log may be installed in an aftermarket,* ONLY: OPTIONAL GAS LINE INSTALLATION permanently located, manufactured (mobile) home, where not prohibited by local codes. GAS LINE HOOK UP SHOULD BE DONE BY YOUR *Aftermarket: Completion of sale, not for purpose of resale, SUPPLIER OR A QUALIFIED SERVICE PERSON.
  • Page 10: Chimney Offset

    FIRESTOP SPACERS: (3600FS-8DM) 3. Maximum length of pipe between supports (return elbow or 12S-8DM) is 6’ of angled run. Maximum of two (2) 6’ Firestop spacers are required at each point where the chimney angled run sections per chimney system (see figure 24). penetrates a floor space.
  • Page 11: Damper Operation

    FIREPLACE FACE EXTENSION: (FE-36) A fireplace face extension is available for use with this fireplace as an optional part. To install, secure the fireplace face extension to the top of the fireplace face with four self-drilling screws (provided) as shown in figure 25.
  • Page 12: Replacement Parts And Accessories

    REPLACEMENT PARTS ACCESSORY PARTS VENT KIT PART NUMBERS SEE BELOW VENT KITS - USE FOR MOST COMMON MANUFACTURED (MOBILE) HOME INSTALLATIONS CONTENTS CPMH-A/AC CPMH-ACA CPMH-A/ACB 8' vent kit 9' vent kit 9' vent kit 36-8DM 36" Double Wall Pipe 24-8DM 24" Double Wall Pipe 18-8DM 18"...
  • Page 13 P/N 035-16689-000...