I/O pin
Low (L)
Input
Max. 0,5 V
Output
Max. 0,3 V
• A not connected input is on high level (H).
• Output is protected from overcurrent by electronic retracting safety-fuse.
• The +4V clip is intended for power supply of a possible front-end logic. Maximum
load is 150 mA.
Functions and recommended connection of external input and output circuits:
Binary input/output circuits have to be configured for each required function using the
GB 060 Control Panel software.

2.2.3. Relay Output

The relay output is a galvanically separated
output for direct control of power appliances.
The output is led out to a 6-pin connector
marked with two Re symbols.
The relay output must be configured by the
GB 060
Control
requested action, and then it is possible to:

2.2.4. LED Output

An output for a LED that can be located out of GB 060. The output is led out to a 6-pin
connector marked with the L+ and L symbols.
The LED indicates these states of GB 060:
• the LED is off
• blinks each 0.1 sec for a period of 1 sec
• blinks twice per 0.1 s for a period of 3 sec group 1 is active, but there is no GSM
Min. 3 V, Max. 30 V
Open Collector, Max 50 V
Bias 3,3 V / 115 kΩ
Panel
software for
High (H)
the
group 1 is inactive (unlocked)
group 1 is active (locked – basic state)
signal
9
Load
Input
Carrying
Resistance
Capacity
Approx. 15
kΩ
0.5 A