San Mapping With Multipath And Duplexwrite In Switch Configuration - Fujitsu Siemens Computers Primergy S60 Technical Configuration Manual

Fujitsu primergy s60 storage subsystem technical configuration guide
Hide thumbs Also See for Primergy S60:
Table of Contents

Advertisement

Configurations
3.4.5
SAN Mapping with MultiPath and DuplexWrite in
Switch Configuration
Configuration hints
Fibre-Topology: Multi Port
LUN Mapping: affinity to all ports, host-to-LUN-mapping
up to four PRIMERGY servers are released
in configurations with switches MMF is the preferred connection medium
DuplexDataManager (MultiPath and DuplexWrite) necessary
QLA 2200 settings: see table 9 on page 51, Submenu 1.6.3: Connection
Options/Point to Point Only (1)
Loop IDs (figure 30 on page 46) for FFx, HBAs disabled
Settings
Ê Set DIP switches on FFx-RAID controller/host adapter (HA board) (see
section "DIP Switches Settings for Different Connections" on page 6).
P15355-P111-Z139-5-7619