Configuring the FFx-RAID Ctlr.
Ê Open the Fibre dialog box and set the parameters as shown in figure 7.
2.2.2

Dual Active Configuration

Use the same procedure for setting the controller parameter in a dual active
configuration as shown in the figures below.
I
When both FFx controllers are in the same loop, the mapping of
controller Hard Loop IDs to Target IDs for ordering of the disks depends
on the Operating System, and different operating systems do this differ-
ently (Windows NT4 vs. Windows 2000).
If you wish to have the disks with lower numbers on controller C0, you
may have to exchange the Hard Loop IDs of the DAC FFx controllers.
Figure 8: SAM Controller Information Window (dual active)
P15355-P111-Z139-5-7619
FFx-RAID Controller Parameter Settings
13