Maintenance; Daily Maintenance; Monthly Maintenance - Antunes, AJ Series 9100100 Owner's Manual

Deluxe food warmer 9100100 series
Table of Contents

Advertisement

Fault Codes
When the programming parameters for Minutes/
Seconds/SHO/H2O have been inadvertently changed
to a setting below or above their limits, the unit displays
the "ERR" fault code. If this code appears, you must
clear these settings using the following procedure:
1. Turn the Rocker Switch (power On/Off) to OFF.
2. Press and hold the Program and the Start/Stop
buttons simultaneously.
3. Turn the unit on while holding the buttons.
Release the buttons when the unit stops beeping.
NOTE: Repeat Steps 1 through 4 if the unit still dis-
plays the "ERR" fault code.
4. The display will now register 15:00.
NOTE: It is recommended that the SHO and H2O
settings be adjusted to the recommended settings
WARNING
Turn the unit off, disconnect the power source
and allow the unit to cool down before performing
any service or maintenance on the unit.
WARNING
Be sure to follow all of the precautions, proce-
dures, and safety steps listed in the Important
Safety Information section of this manual.
NOTE: Frequency of cleaning is determined by
water conditions, usage and water filter systems.
CAUTION
Do not use a sanitizing solution or abrasive mate-
rials. The use of these may cause damage to the
stainless steel finish.
CAUTION
If a chemical cleaner is used, be sure it is safe to
use on cast aluminum. Observe all precautions
and warnings on product label.
NOTE: Frequency of cleaning is determined by
water conditions, usage and water filter systems.

Daily Maintenance

1. Turn the Rocker Switch (power On/Off) to OFF,
unplug the power cord, and allow the unit to cool
down before proceeding.
P/N 1010678 Rev. F 09/04
OPERATION (continued)
shown in the Programming section of this manual.

MAINTENANCE

2. Check the Water Pressure Regulator gauge
3. Remove the Trivet and Pan (Figure 10).
4. Wash items in hot, soapy water and then rinse
5. Wipe down the Top Cover, Gasket, and the entire
6. Re-install Diffuser, Pan and Trivet.
NOTE: Allow Top Cover to remain open overnight.

Monthly Maintenance

The Deluxe Food Warmer utilizes an open steam gen-
erator. Water sprayed onto the generator surface flash-
es into steam immediately, but the minerals in the water
do not steam. They stay on the generator surface. A
small amount of calcium/mineral deposits are need-
ed for proper operation, but a build-up of excessive
calcium/mineral deposits causes poor steaming efficien-
cy, excessive moisture (wet steam), and will eventually
severely retard the steaming action completely.
15
DELUXE FOOD WARMER
�����
���
��
����
�������
�����
Figure 9. "ERR" Fault Code
(DFW/DFWT/DFWF-200/250 units only) and verify
that it reads 20-25 PSI (1.4 - 1.7 kg/cm2 or 138-
172 kPa). If not, adjust the water pressure as
described in the Installation section of this manu-
al. Check the rear water Quick Disconnect Fitting
and Hose Clamp for leakage. Tighten clamps or
replace parts if needed.
and WIPE DRY.
exterior of the unit (Figure 10) with a clean, hot,
damp cloth (not dripping wet ) and wipe dry.
����������

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents