Item
Panel test mode
[Wide]
1) Adj item: [Aw MSK]
Adjust: [✳✳✳✳]
PTT: ON
Press [ ] key to store
the adjustment value.
14. CWID
1) Adj item: [Nv CWID]
Deviation
Adjust: [✳✳✳✳]
adjust *4
Deviation meter
LPF: 3kHz
[Very
HPF: OFF
Narrow]
PTT: ON
Press [ ] key to store
the adjustment value.
*4: Refer to the "Necessary Deviation adjustment item for each signaling and mode" table on page 57.
■ Necessary Deviation adjustment for each signaling and mode
The following shows the necessary adjustment items for each signaling deviation. Please read the following table like the following example. In the
case of the signaling "QT (Wide)", this signaling is composed of three elements [Balance, Maximum Deviation (Analog Wide) and QT Deviation (Wide)].
Please adjust Balance and Maximum Deviation (Analog Wide) before adjusting QT Deviation (Wide).
Mode
Signaling
Step1. Balance adjust
Audio
Step2. Maximum Deviation (Analog Wide)
Step1. Balance adjust
QT
Step2. Maximum Deviation (Analog Wide)
Step3. QT Deviation (Wide)
Step1. Balance adjust
DQT
Step2. Maximum Deviation (Analog Wide)
Step3. DQT Deviation (Wide)
Step1. Balance adjust
LTR
Step2. Maximum Deviation (Analog Wide)
Analog
Step3. LTR Deviation (Wide)
Step1. Balance adjust
DTMF
Step2. Maximum Deviation (Analog Wide)
Step3. DTMF Deviation (Wide)
Step1. Balance adjust
Step2. Maximum Deviation (Analog Wide)
2TONE
Step3. Single Tone Deviation (Analog
Wide)
Step1. Balance adjust
MSK
Step2. Maximum Deviation (Analog Wide)
(FleetSync)
Step3. MSK Deviation (Analog Wide)
Audio
-
NXDN
CEID
-
Balance is common with all the above deviation adjustments. If Balance (Transmitter Section5) has already adjusted, please skip Step1 and adjust from Step2.
Maximum Deviation (Analog Wide/Narrow) is common with all the analog signaling deviations and CWID Deviation (NXDN Very Narrow). If Balance and
Maximum Deviation (Analog Wide/Narrow) (Transmitter Section7) have already adjusted, please skip Step2 and adjust from Step3.
ADJUSTMENT
Condition
PC test mode
equipment
1) Adj item: [MSK
Deviation
Deviation (Wide)]
meter
PTT: Press
Oscilloscope
[Transmit] button.
Press [Apply]
button to store the
adjustment value.
1) Adj item: [CWID
Deviation]
Deviation meter
LPF: 3kHz
HPF: OFF
PTT: Press
[Transmit] button.
Press [Apply]
button to store the
adjustment value.
Wide
Step1. Balance adjust
Step2. Maximum Deviation (Analog Narrow)
Step1. Balance adjust
Step2. Maximum Deviation (Analog Narrow)
Step3. QT Deviation (Narrow)
Step1. Balance adjust
Step2. Maximum Deviation (Analog Narrow)
Step3. DQT Deviation (Narrow)
Step1. Balance adjust
Step2. Maximum Deviation (Analog Narrow)
Step3. LTR Deviation (Narrow)
Step1. Balance adjust
Step2. Maximum Deviation (Analog Narrow)
Step3. DTMF Deviation (Narrow)
Step1. Balance adjust
Step2. Maximum Deviation (Analog Narrow)
Step3. Single Tone Deviation (Analog Wide)
Step1. Balance adjust
Step2. Maximum Deviation (Analog Narrow)
Step3. MSK Deviation (Analog Wide)
Step1. Balance adjust
Step2. Maximum Deviation (NSDN Narrow)
-
Measurement
Test-
Unit Terminal Unit
ANT
Necessary adjustment and order
Narrow
NX-800/800H
Adjustment
Parts
Method
[Panel
Write the value as
tuning
followings.
mode]
513 (Reference
[ ],[ ]
value)
[PC test
mode]
[ ],[ ]
Write the value as
followings.
375 (Reference
value)
Very Narrow
-
-
-
-
-
-
-
Step1. Balance adjust
Step2. Maximum Deviation (NXDN Very Narrow)
Step1. Balance adjust
Step2. Maximum Deviation (Analog Narrow)
Step3. CWID Deviation (NXDN Very Narrow)
Specifi cations /
Remarks
2.90~3.10kHz
0.90~1.10kHz
57