Travis Industries SKU 99300689 Instructions Manual

Gas/pellet remote thermostat

Advertisement

Quick Links

Compatibility
All Travis Gas Stoves
33 DVI Insert
31 DVI Insert
564 (SS, DF, HO)
Packing List
Transmitter
Receiver
(2) Pieces Hook and Loop Tape
Pellet Stove Connector Wires
FCC Requirements
Warning: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void
the user's authority to operate the equipment. This equipment has been tested and found to comply with the limits for a
Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency
energy and, if not installed and used in accordance with the instructions,, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a particular installation. If this
equipment does cause harmful interference to radio or television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiver.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio TV technician for help.
Canadian Equipment Requirements
This digital apparatus does not exceed the (Class A/Class B) limits for radio noise emissions from digital apparatus
set out in the Radio Interference Regulations of the Canadian Department of Communications. Le present appareil
numerique n'emet pas de bruits radioelectricques depassant les limites applicables aux appareils numeriques (de
la class A/de la class B) prescrites dans le Reglement sur le brouillage radioelectrique edicte par le ministere des
Communications du Canada.
This device complies with RSS-210 of Industry and Science Canada. Operation is subject to the following two
conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including
interference that may cause undesired operation of the device.
Installation Warnings
! Shut off power to the appliance and allow it to cool prior to installation.
! This kit must be installed by a qualified technician.
! All 110 VAC wiring must be done by a qualified electrician and shall be in compliance with local codes and the
National Electric Code ANSI/NFPA No. 70 (in the United States), or with the current CSA C22.1 Canadian
Electric Code (in Canada).
! Do not connect 110 VAC to the gas control valve or on/off switch on gas heaters or the thermostat posts on pellet
heaters.
Follow the instructions on the following pages for the type of model being addressed.
This Remote Is Not Intended For Extended Un-Attended Use
If the batteries in the transmitter go dead or if the transmitter is placed somewhere out of range, the heater will not turn
on or off based upon room temperature. For this reason, do not use the remote for installations that provide the sole
source of heat or where remote operation is imperative.
Page 1 of 8
Gas/Pellet Remote Thermostat
SKU 99300689
864 (TRV, HO, ST)
21 TRV GS
All Travis Pellet Stoves or Inserts (1997 or later)
Gas Stove/Insert Connector Wires
("Y" Jumper Wires)
Power Cord Adapter (for gas appliances)
Transmitter Mounting Bracket with hardware
(for hanging the transmitter on the wall)
3/7/12 - 17601682
© Travis Industries, Inc.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SKU 99300689 and is the answer not in the manual?

Questions and answers

Summary of Contents for Travis Industries SKU 99300689

  • Page 1 For this reason, do not use the remote for installations that provide the sole source of heat or where remote operation is imperative. Page 1 of 8 3/7/12 - 17601682 © Travis Industries, Inc.
  • Page 2 See “Power Cord Adapter Installation” for details. Place the receiver on the right side floor of the firebox, as far away from the insert as possible (minimum 1" clearance to side of insert). Page 2 of 8 3/7/12 - 17601682 © Travis Industries, Inc.
  • Page 3 If using a blower you will need to disconnect the blower power lead and attach it to the power cord adapter. Optional Accent Blower Light Lead Lead 120 VAC Power In Power Adapter (included with remote) Remote Receiver Ground 6V AC Adapter for Fireplace Burner Control Page 3 of 8 3/7/12 - 17601682 © Travis Industries, Inc.
  • Page 4 (orientation does not mater). Bundle up any excess wire with a lock-tie to prevent it from contacting any hot or moving parts Page 4 of 8 3/7/12 - 17601682 © Travis Industries, Inc.
  • Page 5 6. The “F” or “C” display will flash. Use the “Up” and “Down” Fahrenheit or arrow buttons to select Fahrenheit or Celsius. Celsius Display 7. Press the “CLOCK” button again. Programming is complete. “UP” and “Down” Arrows Page 5 of 8 3/7/12 - 17601682 © Travis Industries, Inc.
  • Page 6: Modes Of Operation

    TO TURN ON AND OFF: Use this key to toggle the heater on and off. The display will indicate the status. NOTE: -- If the room exceeds 90°, the heater will shut off. Page 6 of 8 3/7/12 - 17601682 © Travis Industries, Inc.
  • Page 7: Thermostat Mode

    The heater will turn on and stay running for the number of minutes displayed. NOTE: If the room exceeds 90°, the heater will shut off. Page 7 of 8 3/7/12 - 17601682 © Travis Industries, Inc.
  • Page 8: Child Proof Feature

    (if the remote calls for heat) within 30 minutes. If you wish to over-ride the remote and turn the heater on (gas stoves only), turn the on/off switch on the gas heater to "ON". Page 8 of 8 9/10/12 - 17601682 © Travis Industries, Inc.

This manual is also suitable for:

99300689

Table of Contents