Installation Guide BRIGADE Viking Range, LLC 111 Front Street Greenwood, Mississippi 38930 USA (662) 455-1200 For product information, call 1-888-(845-4641) or visit our web site at brigade.ca Professional Built-In Electric Single and Double Ovens F21103B EN (063014)
Page 2
Table of Contents IMPORTANT–Please Read and Follow! Warnings & Important Safety Instructions _______________________________________________3 • Before beginning, please read these Your safety and the safety of others is Dimensions-Professional Single________________________________________________________6 instructions completely and carefully. very important. Specifications & Electrical Requirements-Professional Single ______________________________8 •...
Page 3
IMPORTANT– IMPORTANT– Read and Follow! Read and Follow! A GFI shall be used if required by NFPA-70 (National Electric Code), federal/state/local laws, or local ordinances. WARNING DANGER • The required use of a GFI is normally related to the location of a receptacle with respect to any significant sources of water or moisture.
Page 4
Single Oven Dimensions Single Oven Dimensions (Select / Premiere Models) (Select / Premiere Models) (For cutout dimensions - refer to pages 9 and 10) (For cutout dimensions - refer to pages 9 and 10) 30” Wide 27” Wide Rating Label Location Rating Label Location...
Page 5
Specifications & Electrical Requirements Cutout Dimensions–Single Oven (For Flush mount cutout dimensions - Refer to pages 16 - 23) Note: A minimum of 2” (5.1 cm) spacing above and below the oven to any adjacent appliances such as a microwave or warming drawer is required for ventilation purposes. Professional Single Oven Description - 27”...
Page 8
Cutout Dimensions–Double Oven Cutout Dimensions–Double Oven (For Flush mount cutout dimensions - Refer to pages 16 - 23) (For Flush mount cutout dimensions - Refer to pages 16 - 23) Note: A minimum of 2” (5.1 cm) spacing above and below the oven to any adjacent appliances such as a microwave or warming drawer is required for ventilation purposes.
Page 9
Dimensions Dimensions (27” Single Oven flush mount installation) (27” Double Oven flush mount installation) LEGEND LEGEND Blocking Blocking Finished Finished Surfaces Surfaces Finished Finished Surfaces Surfaces Vertical Vertical Blocking Blocking 3/4” Base Blocking 3/4” Base Blocking DOUBLE OVEN SINGLE OVEN FLUSH CUTOUT FLUSH CUTOUT 26-15/16”...
Page 10
Dimensions Dimensions (27” Flush mount installation) (27” Flush mount installation) Side View Top View Distance will vary depending on the cabinet Vertical Blocking Vertical Blocking Screw Screw CRITICAL DIMENSIONS LEGEND 26-15/16” (68.4 cm) Blocking 2-1/2” (6.4 cm) 1/2” (1.3 cm) Cabinet Cross Section CRITICAL...
Page 11
Dimensions Dimensions (30” Single Oven flush mount installation) (30” Double Oven flush mount installation) NOTE: French Door Models (CVDOF730) cannot be installed as a flush mount due to needed allowance for door swing clearance. LEGEND LEGEND Blocking Blocking Finished Finished Surfaces Surfaces Finished...
Page 12
Dimensions Dimensions (30” Flush mount installation) (30” Flush mount installation) NOTE: French Door Models cannot be installed as a flush mount due to NOTE: French Door Models cannot be installed as a flush mount due to needed allowance for door swing clearance. needed allowance for door swing clearance.
Installation General Information • All openings in the wall behind the Recommendations for Site Preparation • It is recommended that 3/4” or larger appliance or in the floor under the Unpacking material be utilized to create a support appliance should be sealed. Note: It is recommended that a thorough platform for this appliance.
Page 14
Installation Procedure Installation Procedure (Select / Premiere Models) (Select / Premiere Models) Green White White Neutral Neutral Green Black Black Wiring option 2* Wiring option 3* Remove hinge trim screws. Take off hinge trim. Close until pins stop door. (connect the white to the incoming neutral, (connect the white to the incoming neutral, attach green to grounded junction box) attach green to suitable ground)
Page 15
Installation Procedure Installation Procedure (Select / Premiere Models) (French Door Models) Open lower door completely. Place pin in pin hole. Remove wooden brace on front of pallet. Replace door. Open door completely. Put hinge trim plates back on. DO NOT remove the top French Doors. Note: Screw holes may need to be re-aligned.
Page 16
Installation Procedure Installation Procedure (French Door Models) (French Door Models) White Neutral Green Black Wiring option 1* Attach screws to the side of the framing. Replace racks. Unscrew pallet screws from side of oven. (connect the white and green to the incoming neutral) Note: 2 screws for single ovens, 4 screws for double ovens (screws not included) Green...
Performance Checklist Installation Procedure (French Door- Upper Door Adjustment) There may be ocassions where the upper doors are not aligned to the same height, especially if CAUTION: Do not run self-clean cycle check A qualified installer should carry out the doors were removed for maintenance and then reinstalled.
Performance Checklist Final Preparation Service & Parts (continued) Only authorized replacement parts may be 1. Some stainless steel parts may have a Professional Series–Select used in performing service on the range. plastic protective wrap, which must be Self-Clean Electronic Off/On Temperature Do not repair or replace any part of the Indicator light...