Hitachi CP-SX1350 P5SX+ Service Manual page 14

Multimedia lcd projector
Table of Contents

Advertisement

DC fan malfunction
Measure the voltage
at each pin
Set AC to ON and
enter standby status
The voltage is
H (3.3V)
Turn on the
power supply and check
the voltage
The voltage
(about 1 sec.)
H (3.3V)
OK
Check the fan connector
connection
FAN
NG
Connector connection
CP-SX1350(P5SX+)
Lamp does not light
What is the state of
LAMP indicator DK52
during operation?
Not light
H (3.3V)
DC FAN
PANEL B : E801
1
PANEL G : E802
1
PANEL R : E803
1
EXHAUST : E804
1
INTAKE : E809
1
LAMP : E808
1
once
Normal
to L (0V)
about 1 sec.
H
OK
AC ON Power ON
H
NG
Is the
voltage at collector
Light
of Q801 on the PWB assembly
Drive fixed to "L" during
warming-up?
NO
Change the lamp.
Does lamp light?
Not light
Power unit (ballast)
Blinks
state of TEMP indicator
(DK 53 on the KEYPAD
Measure
sure voltage at
TP-FS and/or TP-FS2 on
the PWB assembly
Drive.
at pin
L (0V)
the PWB assembly Drive
PWB assembly Drive
Power unit (ballast)
14
YES
PWB assembly Drive
"L" = 0V
Light
Lamp
Power unit (circuit)
What is the
board)?
Not light
Is the voltage
of E805 on
3
NO
set to "L" during
"L" = 0V
warming-up?
YES
PWB assembly Drive
(L = less
than 1.5V)

Advertisement