28
The OSD for the Intelli Proof/Color 190, 201, 213 ,
213 excellence and Proof View 700 offers the follo-
wing functions:
- Input
- Auto Setup (analogue)
- Brightness (luminance)
- Contrast (analogue)
- Image (analogue)
- Calibration (only used for Intelli Color)
- Frequency/Phase (analogue)
- Management
To select the connection, choose Input.
Auto Setup performs an automatic adjustment when
a VGA signal is used.
Brightness controls the backlight brightness.
Contrast is only available if the display is used in
VGA-mode.
Image adjusts position and size of the image in ana-
logue mode.
The Calibration Menu is used to adjust the manual
calibration values of the Intelli Color 190, 201 and
213. Select the preset that matches your setup clo-
sest, and adjust the RGB values.
- HW calibration (Hardware Calibration)
- RGB 1.8 (RGB adjustment with Gamma 1.8)
- RGB 2.2 (RGB adjustment with Gamma 2.2)
- RGB L* (RGB adjustment with L* Gradation)
- D55-1.8 (5.500K with Gamma 1.8)
Notice:
Some older displays do not allow separate
RGB adjustments. If an Intelli Proof 190/201/213 is
used, the calibration software will switch the display
to hardware calibration mode.
Frequency and phase can be used to finetune an
image if the Auto Setup results in a suboptimum
image performance.
Management is used to select languages, to change
the OSD position and to reset the whole unit.