Measuring
Item
instrument
H. BOW
Signal
adjustment
generator
Remote
control unit
4.7.6 VSM PRESET SETTING
Measuring
Item
instrument
VSM
Remote
PRESET
control unit
setting
SUB MENU 5. VSM W/B
1-24 (No.YA252)
Test point
Adjustment part
[4.DEF]
11. BOW
Straight
Test point
Adjustment part
[5. VSM W/B]
1. BRIGHT
2. CONT
3.COLOUR
4. SHARP
5. HUE
1. R-DRIVE
2. G-DRIVE
3. B-DRIVE
VSM PRESET BRIGHT
1. BRIGHT
***
Description
- PAL H. BOW -
(1) Receive a PAL crosshatch signal.
(2) Select 11. BOW.
(3) Set the initial setting value of 11. BOW.
(4) Adjust 11. BOW to optimize the horizontal arc
distortion.
- NTSC H. BOW -
(1) Input a NTSC crosshatch signal.
(2) Make similar adjustment of NTSC H. BOW in the
same way as for "PAL H. BOW".
(3) Press the [DISPLAY] key twice to return to the
normal screen.
Description
(1) Select 5. VSM W/B from the SERVICE MENU.
(2) Select BRIGHT with the MENU [OK] key.
(3) Set the value of 1. BRIGHT ~ 5. HUE to the values
shown in the table.
(4) Respectively select the VSM PRESET mode for
SOFT and STANDARD.
(5) Select COOL with the MENU [OK] key.
(6) Set the values of 1. R-DRIVE ~ 3. B-DRIVE to the
value shown in the table.
(7) Select the W/B preset for WARM and NORMAL,
respectively.
(8) Press the [DISPLAY] key twice to return to the
normal screen.
[Setting Values for SUB 5. VSM W/B]
VSM preset
BRIGHT
Setting item
1. BRIGHT
0
2. CONT
+15
3. COLOUR
0
4. SHARP
0
5. HUE
0
W/B preset
COOL
Setting item
1. R-DRIVE
0
2. G-DRIVE
0
3. B-DRIVE
0
STANDARD
SOFT
+4
+4
+4
+1
0
0
0
-10
0
0
NORMAL
WARM
0
+10
+2
-4
-10
-12