CAUTION: Equipment Damage
¾ When connecting cables from the inverter to the battery terminals, ensure
¾ Thoroughly inspect the equipment prior to energizing. Verify that no tools
¾ Ensure clearance requirements are strictly enforced and that all vents are
¾ Sensitive electronics inside the equipment can be destroyed by static

PV Safety

WARNING: Shock Hazard
Photovoltaic (PV) arrays can be energized with minimal ambient light available.
Therefore to ensure a safe disconnect from the system, be sure to install a PV
disconnect, breaker, or accessible fuse box (depending on local code
requirements).
CAUTION: Equipment Damage
PV Arrays must be wired with correct polarity (positive-to-positive, negative-to-
negative). Connecting the cables incorrectly can damage or destroy the
equipment.

Battery Safety

WARNING: Electrocution Hazard
¾ Use the battery types recommended by OutBack Power Systems. Follow
¾ Ensure clearance requirements are strictly enforced around batteries.
¾ Ensure the area around the batteries is well ventilated and clean of debris.
¾ Always use insulated tools. Avoid dropping tools onto batteries or other
¾ Keep plenty of fresh water and soap nearby in case battery acid contacts
¾ If you need to remove a battery, always remove the ground terminal from
¾ If a remote or automatic generator control system is used, disable the
4
the proper polarity is observed. Connecting the cables incorrectly can
damage or destroy the equipment.
or equipment have been inadvertently left behind.
clear of obstructions that can prevent proper air flow around or through
the unit.
electricity. Be sure to discharge any static electricity built up before
touching the equipment and wear appropriate protective gear.
the battery manufacturer's recommendations for installation and
maintenance.
electrical parts.
skin, clothing, or eyes.
the battery first. Make sure all accessories are turned off so you don't cause
a spark.
automatic starting circuit and/or disconnect the generator from its starting
battery while performing maintenance to prevent accidental starting.
Important Safety Instructions
900-0033-01-00 Rev A

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SmartRE 3000 and is the answer not in the manual?

Subscribe to Our Youtube Channel

This manual is also suitable for:

Smartre 2500Smartre 5000Smartre 6000

Table of Contents