2.3.17 Sensor Plate (Inlet)

(1) Remove the upper cover (see 2.3.1).
(2) Remove the operator panel assy (see 2.3.3).
(3) Remove the face up stacker assy (see 2.3.8).
(4) Remove the lower base unit (see 2.3.4).
(5) Press the clamps of three sensor plates (inlet and paper) 1, and remove them by pressing them
upward from the bottom. When removing the sensor plates, take care not to lose the springs.
Note : Be careful not to touch (or rotate) the DC motor thoughtlessly. Rotating the DM motor
counterclockwise removes the eject spring. (Refer to 2.3.9.)
43502101TH Rev.1
1
Spring sensor write
1
Sensor plate (paper)
1
Spring sensor IN
Sensor plate (inlet)
Oki Data CONFIDENTIAL