Specifications - Dometic Duo-Therm 57915.331 Installation Instructions Manual

579/595 series brisk air, quick cool roof top air conditioners used with cooling & furnace, cooling, furnace & heat strip remote comfort control kit ducted
Table of Contents

Advertisement

MODEL
NOMINAL
ELECTRICAL
NO.
CAPACITY
RATING
(BTU/HR)
COOLING
115VAC,
57915.331
13,500
57915.336
13,500
60 HZ., 1PH.
57915.531
13,500
57915.536
13,500
57915.541
13,500
57915.546
13,500
57915.631
13,500
57915.731
13,500
59516.331
15,000
59516.336
15,000
59516.531
15,000
59516.536
15,000
59516.631
15,000
*
For wire lengths over 24 ft. consult the National Electric Code for proper sizing.
Dometic Corporation gives GENERAL guidelines for generator requirements. These guidelines come from experiences people have had in actual applications
**
When sizing the generator, the total power usage of your recreational vehicle must be considered. Keep in mind generators lose power at high altitudes and
from lack of maintenance.
***
CIRCUIT PROTECTION: Time Delay Fuse or HACR Circuit Breakers Required.
COMPRESSOR
COMPRESSOR
FAN MOTOR
RATED LOAD
LOCKED
RATED LOAD
AMPS
ROTOR
AMPS
AMPS
11.4
58.0
2.5
11.4
58.0
2.5
12.1
59.0
2.5
12.1
59.0
2.5
11.3
62.0
2.5
11.3
62.0
2.5
11.0
54.4
2.5
11.3
56.0
2.5
11.5
50.0
2.5
11.5
50.0
2.5
11.5
50.0
2.5
11.5
50.0
2.5
12.3
77.0
2.0

SPECIFICATIONS

FAN MOTOR
SCFM-HIGH
TOTAL
LOCKED
SPEED
STATIC
ROTOR
MAX/MIN
MIN/MAX
AMPS
" W. C.
5.8
325 / 250
0.55 / 0.90
5.8
325 / 250
0.55 / 0.90
5.8
325 / 250
0.55 / 0.90
5.8
325 / 250
0.55 / 0.90
5.8
325 / 250
0.55 / 0.90
5.8
325 / 250
0.55 / 0.90
5.8
325 / 250
0.55 / 0.90
5.8
325 / 250
0.55 / 0.90
5.8
325 / 250
0.40 / 1.10
5.8
325 / 250
0.40 / 1.10
5.8
325 / 250
0.40 / 1.10
5.8
325 / 250
0.40 / 1.10
5.6
325 / 250
0.40 / 1.10
REFRIGERANT
MINIMUM
AC CIRCUIT
R-22 (OZ.)
WIRE SIZE*
PROTECTION
*** USER
SUPPLIED
15.5
12 AWG
20 Amp
15.5
Copper
20 AMP
16.5
up to 24'
20 Amp
16.5
20 Amp
16.0
20 Amp
16.0
20 Amp
16.5
20 Amp
15.0
20 Amp
29.0
20 Amp
29.0
20 Amp
26.5
20 Amp
26.5
20 Amp
29.5
20 Amp
INSTALLED
MINIMUM
WEIGHT
GENERATOR
(POUNDS)
SIZE**
1 UNIT/ 2 UNITS
100
3.5 KW / 5.0 KW
100
3.5 KW / 5.0 KW
94
3.5 KW / 5.0 KW
94
3.5 KW / 5.0 KW
94
3.5 KW / 5.0 KW
94
3.5 KW / 5.0 KW
94
3.5 KW / 5.0 KW
94
3.5 KW / 5.0 KW
94
3.5 KW / 5.0 KW
94
3.5 KW / 5.0 KW
94
3.5 KW / 5.0 KW
94
3.5 KW / 5.0 KW
104
3.5 KW / 5.0 KW

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents