TRANSPORTING/STORAGE
When transporting the engine, turn the fuel valve OFF and keep
the engine level to prevent fuel spillage. Fuel vapor or spilled fuel
may ignite.
Befor storing the unit for an extended period;
1.
Be sure the storage area is free of excessive humidity and dust.
2.
Drain the fule...
Gasoline is extremely flammable and is explosive under certain
conditions. Do not smoke or allow flames or sparks in the area.
a.
With the fuel valve in the OFF position,
remove and empty the sediment cup.
b.
Turn the fuel valve to the ON position
and drain the gasoline from the fuel
tank into a suitable container.
c.
Replace the sediment cup and tighten
securely.
d.
Drain the carbretor by loosening the
drain screw. Drain the gasoline into a
suitable container.
3.
Change the engine oil (page 20).
4.
Remove the spark plug and pour about a tablespoon of clean
engine oil into the cylinder.
Crank the engine several revolutions to distribute the oil, then
reinstall the spark plug.
5.
Pull the starter rope slowly until resistance is felt.Continue
polling until the notch on the starter pulley aligns with the hole
on the recoil starter (see illustration below). At this point, the
intake and exhaust valves are closed, and this will help to
protect the engine from internal corrosion.
6.
Electric starter type: Remove the battery and store it in a cool;,
dry place. Recharge it once a month.
7.
Cover the engine to keep out dust.
DRAIN
SCREW
Align the mark on the starter
pulley with the hole at the top
of recoil starter.