Dual Fuel Range Specifications
Gas Supply Requirements
EXPLOSION HAZARD: Use a certified gas supply line
and install a gas shut-off valve. Securely tighten all gas
connections. Failure to follow these instructions can
result in explosion, fire or death.
IMPORTANT NOTE: The dual fuel range must be connected
to a regulated gas supply.
IMPORTANT NOTE: This installation must conform with
local codes and ordinances. In the absence of local
codes, installations must conform with the American
National Standard, National Fuel Gas Code.
The dual fuel range is equipped for use with natural or
liquid propane (LP) gas. It is design certified by the
Canadian Standards Association (CSA) for natural or LP
gases. The product rating plate, located on the bottom of
the control panel assembly, at the far right, just above the
oven door, has information on the type of gas that should
be used. Refer to the illustration below. If this information
does not agree with the type of gas available, check with
the local gas supplier.
3
A gas supply line of
/
" rigid pipe must be provided to the
4
range. If local codes permit, a certified, 3' (.9 m) long,
1
3
/
" or
/
" ID flexible metal appliance connector is recom-
2
4
mended to connect the range to the gas supply line. For
LP gas, piping or tubing size can be
suppliers usually determine the size and materials used on
the system. The pipe coming out the back of the range
1
has
/
" female threads. Pipe joint compounds, suitable for
2
use with natural or LP gas should be used.
Locate the gas supply within the shaded area shown in
the illustration for your specific model on the following
pages.
IMPORTANT NOTE: The supply line must be equipped
with an approved external gas shut-off valve located near
the range in an accessible location. Do not block access
to the shut-off valve. Refer to the illustration below.
Wolf natural gas ranges will function up to an altitude of
10,250' (3124 m) without any adjustment. LP gas ranges
will function up to 8,600' (2621 m) without adjustment.
If the installation exceeds these elevations, contact your
authorized Wolf dealer for a high altitude conversion kit.
Before connecting the gas supply, make sure all valves
are in a closed position. Do not connect the gas supply
to an appliance that shows any sign of damage.
RATING PLATE
Location of rating plate.
1
/
" minimum. LP gas
2
SHUT-OFF VALVE
OPEN POSITION
TO APPLIANCE
GAS SUPPLY
Gas shut-off valve.
8