Trouble-shooting.
Malfunction Description
Vacuum cleaner cannot be
switched on.
Reduced vacuuming capacity.
No suction capacity when wet
vacuuming.
Maintenance.
Before mounting or replacing accessories, pull the plug. This preventive safety
WARNING
measure rules out the danger of injuries through accidental starting of the vac-
uum cleaner.
Service
Have maintenance carried out
WARNING
only through qualified person-
nel. Incorrectly mounted conductors and com-
ponents can cause serious injuries. Have the
required service carried out only through a
FEIN customer service agent.
When replacing the power tool's cord is
required, have this carried out by FEIN
or by an authorized FEIN Service Agent, in
order to avoid hazardous situations.
Cleaning
Prior to any cleaning or main-
WARNING
tenance, disconnect the vac-
uum cleaner from the power supply in order to
avoid accidents.
Possible Cause
Circuit breaker has tripped.
Vacuum cleaner in remote
control operation.
Vacuum cleaner not fitted
correctly.
Vacuum system clogged.
Paper-dust bag full.
Filter cartridge or textile per-
manent filter soiled/dirty.
Container full.
Do not use cleaning agents and solvents
that can cause damage to plastic parts.
These include: Gasoline, carbon-tetrachlo-
ride, chloric solvents, ammonia and domestic
cleaning agents that contain ammonia.
Warranty and liability.
The warranty for the product is valid in
accordance with the legal regulations in the
country where it is marketed.
In addition, FEIN also provides a guarantee in
accordance with the FEIN manufacturer's
guarantee. For further details on this, please
contact your specialist dealer, your national
FEIN representative, or the FEIN customer
service center.
Environmental protection,
disposal.
Packaging, worn out vacuum cleaners and
accessories should be sorted for environ-
ment-friendly recycling.
Corrective Action
Ensure power supply.
Set On/Off switch to "I".
Mount vacuum lid and shut
both fasteners completely.
Clean vacuum hose and
extension tubes.
Replace paper-dust bag.
Clean or renew filter cartridge
or textile permanent filter.
Empty container.