26A Charging System; Power Transmission; V-Belt Connections - Honda GX630 Technical Manual

Hide thumbs Also See for GX630:
Table of Contents

Advertisement

26A Charging System

Bl
Black
Br
Y
Yellow
O
Bu
Blue
Lb
Lg
G
Green
R
Red
P
W
White
Gr
COMBINATION SWITCH
IGN GND
BAT
OFF
ON
ST
SPARK
PLUG
OIL
LEVEL
SWITCH
P
T
OWER
RANSMISSION

V-Belt Connections

Be sure there is no static axial load applied to the crankshaft.
Install the pulley as close to the base of the PTO shaft as
possible. When installing the pulley at the end of the PTO
shaft, be sure the overhang of the pulley is less than 50 mm
(2.0 in) as shown.
Before securing the engine and attachment to the engine bed, verify that the V-groove of the engine pulley and
attachment pulley are aligned and that the engine PTO shaft and attachment driven shaft are parallel.
16
Brown
Orange
Light blue
Light green
Pink
Gray
LO
ST
No. 2
IGNITION
COIL
SPARK
PLUG
No. 1
FUEL CUT
IGNITION
SOLENOID
COIL
GX630 • GX660 • GX690 Technical Manual
CHARGE
COIL
(26 A)
(Gr)
(Gr)
(Gr)
(Gr)
(Gr)
(Gr)
(Bl)
(Bl)
(Bl/Y)
(Bl/Y)
BATTERY
STARTER
MOTOR
CRANKSHAFT
© 2010 American Honda Motor Co., Inc — All Rights Reserved
Gr
Gr
Gr
W/Bu
W
Bl
REGULATOR/
RECTIFIER
W
W
FUSE (40 A)
W
W
COMBINATION
SWITCH
PULLEY
Axial
Load =0
50 mm (2 in)
MAXIMUM

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gx660Gx690

Table of Contents