Optional Gas Line Installation - Superior Merit WRT2036WS Installation And Operation Instructions Manual

Merit series wood burning fireplaces
Table of Contents

Advertisement

A gas line or gas log lighter may be installed for the purpose of
installing a vented or vent-free decorative gas appliance incorporat-
ing an automatic shutoff device and complying with the Standard
for Decorative Gas Appliances for Installation in Vented Fireplaces,
ANSI Z21.60 or American Gas Association draft requirements for
Gas Fired Log Lighters for Wood Burning Fireplaces, Draft NO. 4
dated August, 1993.
If you wish to install an unvented (vent-free) gas log set, only
unvented gas log sets which have been found to comply with the
standard for unvented room heaters, ANSI Z21.11.2 are to be installed
in this fireplace.
Gas line hook up should be done by your supplier or a qualified
service person.
Note: Before you proceed, make sure your gas supply is turned off.
Use only a 1/2" black iron pipe and appropriate fittings.
1. Remove knockout indentation on refractory or firebrick wall
located above refractory hearth floor. Knockout indentation must
be firmly tapped with any solid object, such as a 1/2" dowel, until
it is released. Remove fragmented portions of refractory (see
Figure 21).
2. Remove gas line cover plate located on either side of fireplace and
pull out insulation from gas line conduit sleeve. Save insulation
for reuse.
3. Run a 1/2" black iron gas line into fireplace through rear at
gas line conduit sleeve (if using a raised platform, add height).
Provide sufficient gas line into fireplace chamber for fitting
connection (see Figure 22).
Note: Secure incoming gas line to wood framing to provide rigidity
for threaded end.
4. Repack insulation around gas line and into sleeve opening. Seal
any gaps between gas line and refractory knockout hole with
refractory cement or commercial furnace cement. Install gas
appliance or cap off gas line if desired.
CAUTION: All gas piping and connections must be
tested for leaks after installation is completed. After
ensuring that gas valve is on, apply soap and water
solution to all connections and joints. Bubbles forming
show a leak. Correct all leaks at once. DO NOT USE
AN OPEN FLAME FOR LEAK TESTING AND DO NOT
OPERATE ANY APPLIANCE IF A LEAK IS DETECTED.
LEAK TESTING SHOULD BE DONE BY A QUALIFIED
SERVICE PERSON.
Note: An IHP hood must be installed when using an unvented gas
log set (see Accessories on page 18).
WARNING: Do not operate an unvented gas log
set in this fireplace with chimney removed.
126628-01A

OPTIONAL GAS LINE INSTALLATION

If you install a decorative gas appliance (vented gas log), decorative
gas appliance must comply with the Standard for Decorative Gas
Appliance for Installation in Solid Fuel Burning Fireplaces, ANSI
Z21.60/CSA 2.26 or Z21.84 and shall also be installed in accordance
with ANSI Z223.1/NFPA 54 National Fuel Gas Codes (USA) and CAN/
CGA-B149.1 National Gas And Propane Installation Code (Canada).
Outside of Fireplace
Outside of
Fireplace
Repack
Insulation
materials and increasing the risk of spreading a fire,
do not use fireplace to cook or warm food.
burning, firebox and chimney must be cleaned of soot,
creosote and ashes be a qualified chimney cleaner.
Creosote will ignite if heavily heated.
log, damper must be removed or permanently locked
in fully open position and glass doors must be in fully
open position.
www.Superiorfireplaces.US.com
Gas Line
Conduit
Insulation
Gas
Conduit
Cover
Figure 21 - Gas Line Knockout
Gas
Incoming
Line
1/2" Black
Conduit
Iron Pipe
Seal
Opening
with
Refractory
Cement
Figure 22 - Gas Line Installation
WARNING: To avoid the risk of damaging fireplace
WARNING: If the fireplace has been used for wood
WARNING: When using a decorative vented gas
Side
Firebrick
Finished
Side
1/2" Dowel
Refractory
Knockout
Plug
Side
Firebrick
Finished
Side
Provide Enough
Threaded End for
Fitting Connection
13

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Merit wrt2036wsiMerit wct2036wsMerit wct2036wsi

Table of Contents