You are able to preset alarms before the actual dive. The user programmable
alarms can be set for maximum depth, dive time and time. The alarms activate
when:
The preset maximum depth is reached
- continuous beep series for 24 seconds or until any button is
pressed.
- the maximum depth blinks as long as the present depth value
exceeds the adjusted value.
The preset dive time is reached
- continuous beep series for 24 seconds or until any button is
pressed.
- the dive time blinks for one minute, if no button is pressed.
The preset alarm time is reached
- the current time is shown.
- continuous beep series for 24 seconds or until any button is
pressed.
- the current time blinks for one minute, if no button is pressed.
OXYGEN ALARMS IN NITROX MODE
Three double beeps and the backlight activated for 5 seconds occur, when:
the OLF bar graph reaches 80%. The segments exceeding the 80%
limit start to blink (Fig. 3.24.)
the OLF bar graph reaches 100%.
The blinking of the segments exceeding 80% will stop, when the OLF is not
loading anymore. At that point the PO
Continuous beeps for 3 minutes and the backlight activated for 5 seconds
occur, when:
the set oxygen partial pressure limit is exceeded. The maximum depth
is replaced with a current blinking PO
ascend above the PO
NOTE! When the backlight is turned OFF, it does not illuminate when an
alarm is activated.
36
is less than 0.5 bar.
2
depth limit (Fig. 3.24.).
2
value. You should immediately
2