Refrigerant circuit pipe: Removal - Refitting
AIR CONDITIONING
Equipment required
refrigerant charging station
IMPORTANT
Consult the safety instructions and cleanliness
advice and the operation recommendations before
carrying out any repairs (see Air conditioning:
Precautions for repair).
WARNING
To prevent moisture from entering the system,
place plugs on the cold loop components which are
open to the air.
Note:
Use blanking plugs for the fuel circuits with part
numbers 77 01 208 229 or 77 01 476 857 to plug
any openings exposed to the open air. The y must
be clean. Do not use any which have already been
used to plug a fuel circuit.
Location and specifications (tightening torques, parts
always to be replaced, etc.) (see 62A, Air condition-
ing, Air conditioning: List and location of compo-
nents, page 62A-1) .
REMOVAL
I - REMOVAL PREPARATION OPERATION
a
WARNING
Consult the device's operating manual to avoid
incorrect use.
Drain the coolant circuit using the refrigerant
charging station (see Refrigerant circuit: Drain-
ing - Filling) .
a Disconnect the battery (see Battery: Removal - Re-
fitting) (80A, Battery).
For the pipe between the expansion valve and the
condenser:
a Position the vehicle on a two-post lift (see Vehicle:
Towing and lifting) (02A, Lifting equipment).
AIR CONDITIONING
62A-21
a Remove:
- the front bumper (see Exterior body front trim as-
sembly: Exploded view) and (see Exterior body
front trim assembly: Exploded view) (55A, Exte-
rior protection),
- the air deflector mountings (1) ,
- the air deflector (2) .
For the pipes connected to the expansion valve:
K9K
a Remove the front engine cover.
a Move aside the bulkhead soundproofing.
II - REMOVAL OPERATION
a
WARNING
In order to avoid any refrigerant leaks, do not
damage (deform, twist, etc.) the pipe.
a Remove the refrigerant circuit pipe (see 62A, Air
conditioning, Air conditioning: List and location
of components, page 62A-1) .
a Fit blanking plugs on the pipe openings.
62A
145079