The following tables contain Contact ID and Automatic SIA format reporting codes. See programming sections [320]-[348] for reporting codes.
Contact ID
The first digit (in parentheses) is automatically sent by the control. The second two digits are programmed to indicate specific information about the signal. For
example, if zone 1 is an entry/exit point, you could program the event code as [34]. The central station would receive the following:
*BURG - ENTRY/EXIT - 1 where the "1" indicates which zone went into alarm.
SIA Format - Level 2 (Hard Coded)
The SIA communication format used in this product follows the level 2 specifications of the SIA Digital Communication Standard - October 1997. This format
sends the account code along with its data transmission. The transmission will look similar to the following at the receiver:
N ri1
BA 01
N
= New Event
ri1 = Partition /Area Identifier
BA = Burglary Alarm
01 = Zone 1
A system event will use the Area Identifier ri00.
R e po rt ing C o de
S e c t io n #
Zo ne A larms
[320]-[323]
Zo ne Resto rals
[324]-[327]
Duress A larm
[328]
Opening A fter A larm
[328]
Recent Clo sing
[328]
Cro ss Zo ne (P o lice Co de)
A larm
[328]
B urglary No t Verified
[328]
A larm Cancelled
[328]
[F] Key A larm
[329]
[F] Key A larm Resto ral
[329]
[A ] Key A larm
[329]
[A ] Key A larm Resto ral
[329]
[P ] Key A larm
[329]
[P ] Key A larm Resto ral
[329]
Fail to Repo rt In
[329]
Zo ne Tamper
[330]-[337]
Zo ne Tamper Resto re
[330]-[337]
General System Tamper
[338]
General System Tamper
Resto re
[338]
Keypad Lo cko ut
[338]
Clo sings
[339-341 ]
P artial Clo sing
[341 ]
A uto matic Zo ne B ypass
[341 ]
Special Clo sing
[341 ]
Exit Fault
[341 ]
Openings
[342-344]
Special Opening
[344]
Late to Open
[344]
B attery Tro uble
[345]
C o de S e nt Whe n
Zo ne go es into alarm
Zo ne alarm co nditio n has been resto red
Duress co de entered at keypad
System disarmed with alarm in memo ry
Zo ne alarm o ccurs within two minutes o f system arming
Two zo nes go into alarm during any given armed-to -armed
perio d, o r befo re the po lice co de timer expires
This event is transmitted when a seco nd cro ss zo ne alarm
do es no t o ccur within the cro ss zo ning time
Sent when the system is disarmed after an alarm, but
befo re the expiry o f the alarm cancellatio n timer
Keypad Fire A larm (A larm and Resto re rep. co des sent
to gether)
Keypad Fire A larm Resto re (A larm and Resto re rep. co des
sent to gether)
Keypad A uxiliary A larm (A larm and Resto re rep. co des
sent to gether)
Keypad A uxiliary A larm Resto re (A larm and Resto re rep.
co des sent to gether)
Keypad P anic A larm (A larm and Resto re rep. co des sent
to gether)
Keypad P anic A larm Resto re (A larm and Resto re rep.
co des sent to gether)
A zo ne was no t tripped between the inactivity mo nito ring
windo ws
A zo ne is tampered
A tampered zo ne has resto red
The case/co ver has a tamper alarm
The case/co ver tamper co nditio n has resto red
M aximum number o f inco rret access co des have been
entered at a keypad
System armed (User 01 -1 6, 40 indicated)
One o r mo re zo nes bypassed when system armed
A zo ne was bypassed at the time o f arming
Clo sing (arming) using o ne o f the fo llo wing metho ds:
quick arm, keyswitch, functio n key, maintenance co de,
DLS so ftware, Wireless key
Sent when an Exit Erro r o ccurs and the Entry Delay expires
befo re the system is disarmed
System disarmed (User 01 -1 6, 40 indicated)
Opening (disarming) using o ne o f the fo llo wing metho ds:
Keyswitch, maintenance co de, DLS so ftware, wireless key
The system was no t disarmed when the late to o pen time
expired
P C91 55 system battery is lo w
APP-1
Appendix A: Reporting Code Formats
D ia le r
A ut o m a t ic
D ire c t io n
C o nt a c t ID C o de s
A /R
A /R
See Table 3
E(1 )21 -000
A /R
E(4)58-000
A /R
E(4)59-UUU
A /R
E(1 )39-000
A /R
E(3)78-000
A /R
E(4)A 6-UUU
A /R
E(1 )1 A -000
A /R
R(1 )1 A -000
A /R
E(1 )A A -000
A /R
R(1 )A A -000
A /R
E(1 )2A -000
A /R
R(1 )2A -000
A /R
E(1 )A 2-000
A /R
E(3)83-ZZZ
T/R
R(3)83-ZZZ
T/R
E(1 )45-000
T/R
R(1 )45-000
T/R
E(4)61 -000
T/R
R(4)A 1 -UUU
O/C
E(4)56-000
O/C
E(5)7A -ZZZ
O/C
R(4)A A -000
O/C
E(3)74-ZZZ
O/C
E(4)A 1 -UUU
O/C
E(4)A A -000
O/C
E(4)53-000
O/C
E(3)A 2-000
M A /R
S IA A ut o R e p
C o de s
See Table 3
HA -00
OR-00
CR-UU
B M -00/B V-00
B G-00
OC-UU
FA -00
FH-00
M A -00
M H-00
P A -00
P H-00
NA -00
TA -ZZ
TR-ZZ
ES-00
EJ-00
JA -00
CL-UU
CG-00
UB -ZZ
CL-00
EA -ZZ
OP -UU
OP -00
CT-00
YT-00